R25/35CV1A, RY25/35CVMA
3.3

Removal of Electrical Device Mounting Plate

Procedure
Step
1. To remove the shelter.
Remove the three fixed
1
screws for removing the
shelter.
2
Remove the shelter.
2. To remove the
switch
1
Remove all the harness.
2
Remove two fixing
screws of electrical
device mounting plate.
3
Remove the electrical
device mounting plate.
168
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
box.
Si01-406
Points
Removal Procedure