Removal Of Electrical Box - Daikin RKS71KVMA Removal Procedure

Hide thumbs Also See for RKS71KVMA:

Advertisement

Si001167

2. Removal of Electrical Box

Procedure
Step
1
Remove the screw on
the stop valve mounting
plate.
2
Remove the screw on
the partition plate (1).
3
Remove the 2 screws
to detach the earth
wires.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Electrical box
Partition
plate (1)
Stop valve
mounting plate
(R13600)
(R9467)
Earth wire
(R13601)
Removal of Electrical Box