Wiring Diagrams
R35CV1A
TO INDOOR UNIT
1
2
3
L
POWER SUPPLY
~ 50Hz
220V-240V
N
R50CV1A
indoor
FIELD WIRING.
1
2
3
L
N
POWER SUPPLY
~50Hz 220-240V
C11R , C12R : RUNNING CAPACITOR
F1S
: SURGE ARRESTER
F1U
: FUSE
K1M
: COMPRESSOR RELAY
L
: LIVE
192
C11R , C12R : RUNNING CAPACITOR
K1M
GRN
L
YLW
N
M1C
X1M
1
2
3
X2M
L
N
TFU
76ºC
X1M
RED
1
RED
2
WHT
3
GRN
/ YLW
3.15A
F1U
L
BLK
N
BLK
GRN
/ YLW
F1S
M1C : COMPRESSOR MOTOR
M1F
N
Q1L
X11A : CONNECTOR
X1M : TERMINAL STRIP
: COMPRESSOR RELAY
: LIVE
: NEUTRAL
: COMPRESSOR MOTOR
: PROTECTIVE EARTH
RED
4
3
BLU
WHT
5
6
3.15A
14
13
BLK
BLK
F1U
A2
A1
BLK
K1M
Q1L
130
1
2
5
6
RED
C11R
13
14
BLK
A2
A1
RED
C12R
K1M
Q1L
: FAN MOTOR
: NEUTRAL
: OVERLOAD PROTECTOR
: PROTECTIVE EARTH
F1U
: FUSE
M1F
: FAN MOTOR
Q1L
: OVERLOAD PROTECTOR
X1M , X2M : TERMINAL STRIP
TFU
: THERMAL FUSE
BLU
C
M
S
1~
YLW
BRN
RED
M
C11R
BLK
M
1~
RED
WHT
C12R
ºC
BLU
C
M
S
~
YLW
RED
M
M1C
BLK
M
~
RED
WHT
M1F
X11A
outdoor
NOTES
1. REFER TO THE NAMEPLATE FOR
THE POWER REQUIREMENTS.
Si01-406
M1C
M1F
140ºC
3D024714B