Si01-406
4.3
Removal of Compressor
Procedure
Step
Make sure that there is no
refrigerant in the unit
before disassembling.
1
Pull out sound
insulation material
insulation) from right
side.
Disconnect
suction pipe
2
and
discharge pipe
compressor at brazed
sections.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
(side
of
R50/60CV1A
Points
WARNING
If refrigerant gas leaks during
servicing work, ventilate the
area. (If refrigerant gas
contacts flames, hazardous
gas can generate.)
When removing sound-
insulation material, do not
pull it with excessive force,
since it is inserted between
pipes.
179