Si01-406
2.4

Removal of Electrical Parts Box / PCB / Swing Motor

Procedure
Step
1. Remove the front grille.
2. Remove the
drip proof
plate.
1
Loosen the screw.
3. Disconnect the
indoor
heat exchanger thermistor
and the earth.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
FT50/60CV1A
Points
Parts layout
Mind that not to lose the clip
for the thermistor.