Download Print this page

Removal Of Electrical Box - Daikin RKS25E2V1B Service Manual

Removal procedure
Hide thumbs Also See for RKS25E2V1B:

Advertisement

Si001071

2. Removal of Electrical Box

Procedure
Step
1. Remove the electrical
box.
1
Disconnect the 2
connectors for the
reactor.
Cut the clamp.
2
3
Disconnect the
connector for the
compressor [S30].
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
[S30]
Removal of Electrical Box
Points
Preparation
Remove the panels and
disconnect the connector for
the fan motor according to
"Removal of Outer Panels /
Fan Motor".
(R7214)
(R7215)
When reassembling, coil the
excessive lead wire and
hang the loop on the hook.
(R7216)
9

Advertisement

loading

This manual is also suitable for:

Rxs25e2v1bRks35e2v1bRxs35e2v1b