Daikin FT18HEV1K Operation Manual And Installation Manual

Anti-freezing/heating/defrosting/anti-cool wind/gentle functions
Hide thumbs Also See for FT18HEV1K:

Advertisement

MODELS
FT18HEV1K
FT24HEV1K
FT28HEV1K
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL AND
INSTALLATION MANUAL
FTY18HEV1K
FTY24HEV1K
FTY28HEV1K

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FT18HEV1K

  • Page 1 DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL AND INSTALLATION MANUAL MODELS FT18HEV1K FTY18HEV1K FT24HEV1K FTY24HEV1K FT28HEV1K FTY28HEV1K...
  • Page 2: Table Of Contents

    Thank you for purchasing this DAIKIN air conditioner. Before use, carefully read this owner’s manual and keep it in a safe place for future reference. The product in this manual may differ from the model you have purchased. Some models do not have a display.
  • Page 3: Safety Precautions

    Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fi re etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. • The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any fl...
  • Page 4: Installation Site

    • Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. • Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions, moisture in the air may condense and drip.
  • Page 5: Introduction To Basic Functions

    Introduction to basic functions Basic cooling functions Air conditioner function: To bring the ambient temperature to a comfortable level, the air conditioner absorbs heat from inside the room and discharges it outside. Anti-freezing function: If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0°C, the indoor unit microcomputer will stop compressor running and protect the unit.
  • Page 6: Working Temperature Range

    Introduction to basic functions Anti-cool wind function: To prevent cool wind from blowing in Heat mode, the indoor fan will not start if the indoor heat exchanger has not reached the correct temperature within 2 minutes. The anti-cool wind function operates in these conditions: 1.
  • Page 7: Description Of Parts

    Description of parts Indoor unit Air in Air out Symbol shown on the display: : Run : Timer Remote controller Power cable Remote controller Front panel Air filter Guide louver Outdoor unit Wall pipe Air in Bind tape Connection wire Drainage pipe Air out...
  • Page 8: Remote Control Operation

    Remote control operation Description of remote control functions Note: Make sure there are no obstructions between the receiver and remote controller. Do not drop or throw the remote controller. Do not allow liquid to get on the remote controller. Do not put the remote controller in direct sunlight or places that are hot. SLEEP Signal transmitter SLEEP button...
  • Page 9 Remote control operation Description of remote control functions Notice: This remote controller is for general use and can be used for multifunction air conditioners. Some functions are not available on certain models, and even if the corresponding button for such functions on the remote controller is pressed, the unit will be operating at the current running status.
  • Page 10 Remote control operation Description of remote control functions Notice: This remote controller is for general use and can be used for multifunction air conditioners. Some functions are not available on certain models, and even if the corresponding button for such functions on the remote controller is pressed, the unit will be operating at the current running status.
  • Page 11 Remote control operation General Operation (1) Turn the power on and press the ON/OFF button to start/stop operation. (Note: When the unit is powered off, the main unit’s guide louver closes automatically.) (2) Press the MODE button to select a desired operation mode, or enter COOL or HEAT operation modes directly.
  • Page 12 Remote control operation Lock Press + and – buttons simultaneously to lock or unlock the keyboard. If the remote control is locked, is shown. Press any button and the symbol will flicker three times. The symbol disappears when the keyboard is unlocked. Swing Up/Down 1.
  • Page 13: Emergency Operation

    Emergency operation Indicator light control (indoor unit) Use this feature to turn the indicator light on or off. • Turn indicator light on: The symbol displayed on the remote controller shows when the indicator light has been turned on. • Turn indicator light off: The symbol displayed on the remote controller disappears when the indicator light has been turned off.
  • Page 14: Cleaning And Maintenance

    Cleaning and maintenance CAUTION • Make sure to the turn power off and disconnect the power plug before cleaning the air conditioner to prevent the risk of electric shock. • Do not put water directly on surfaces of the indoor or outdoor units. There is a risk of electric shock.
  • Page 15 Cleaning and maintenance Check before use Make sure nothing blocks the air outlet and intake vents. Make sure the ground wire is properly connected. Make sure the air conditioner’s batteries are changed. Make sure the outdoor unit's installation stand is not damaged. If it is damaged, please contact your dealer.
  • Page 16: Troubleshooting

    Troubleshooting CAUTION Do not try to repair the air conditioner; there is danger of electric shock or fire. Please refer to the troubleshooting section before requesting service; you may be able to save time and money. Condition Troubleshooting There is a delay in operation after the air •...
  • Page 17 Troubleshooting Condition Troubleshooting The unit does not operate. • Make sure the power is on. • Make sure the power cord is connected. • Make sure the circuit protection device has not been tripped. • Voltage maybe too high or too low. (To be tested by professionals only) Breaker off •...
  • Page 18 Troubleshooting Condition Troubleshooting Indoor unit does not deliver air. • In HEAT mode, air delivery is delayed until the indoor heat exchanger reaches the correct temperature. (Within 2 minutes.) • In HEAT mode, when the outdoor temperature is cold, frost on the outdoor heat exchanger is defrosted automatically and the indoor unit stops delivering air for 3-12 minutes.
  • Page 19: Safety Precautions

    Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifi es the precautions into WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety. WARNING CAUTION Failure to follow any of WARNING is likely to Failure to follow any of CAUTION may result in result in such grave consequences as death or...
  • Page 20 • During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
  • Page 21: Installation Dimensions

    Air inlet side 30cm or more Space to the wall Space to the wall Space to the wall 50cm or more Air outlet side Model FT18HEV1K FT28HEV1K FT24HEV1K FTY24HEV1K Item FTY18HEV1K FTY28HEV1K Max. Pipe Length (m) Amount of Additional...
  • Page 22: Indoor Unit Installation

    Indoor unit installation Rear panel installation 1. Initially, mount the rear panel horizontally. The indoor unit has drain outlets on the both sides. Adjust the unit so that one of the drain outlets is a little lower than the other one so that flocculated water will be drained from the drain pan.
  • Page 23 Indoor unit installation NOTE: If you find the electrical wiring is of insufficient length for correct installation, please contact an authorized service shop. • The electric wiring must be correctly connected. Incorrect connection can cause spare parts to malfunction. • Tighten the terminal screw correctly. •...
  • Page 24: Outdoor Unit Installation

    Outdoor unit installation Electrical wiring 1. Remove the handle from the outdoor unit’s right side plate. Cooling only models 2. Remove the cord anchorage. Connect the power cord Handle (for cooling and heating unit, connect the power cord N (1) and signal control wire) to the terminal block.
  • Page 25: Installation And Test Operation Checklist

    Installation and test operation checklist Check after installation Items to be checked Possible malfunction The unit shakes, makes noise, or falls out Make sure the unit is securely attached. of position. Refrigerant leakage test. Decreased cooling (heating) effect. Make sure there is sufficient heat insulation. Water condensation or leakage.
  • Page 26 Two-dimensional bar code is a code for manufacturing. 3V007382-8J M10B178 (1008) HT...

This manual is also suitable for:

Ft24hev1kFt28hev1kFty18hev1kFty24hev1kFty28hev1k

Table of Contents