Operating Instructions; Turning On The Stove; Command Center Operations - Vermont Castings Radiance RADVTSCCB Installation And Operating Instructions Manual

Radvt series direct vent gas heater
Hide thumbs Also See for Radiance RADVTSCCB:
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

TURNING ON THE STOVE

Turn on the master switch and wait for a beep. Press the
ON button on the Command Center or turn on wall switch.
Pilot will light and burner will come on High setting or
last memory setting (See Turning Off Stove below). For
memory feature.
Pilot Safety Lockout Function
If the pilot doesn't light after sparking for 30 seconds, pilot
trial lockout happens. The LED on the Command Center
flashes Green once every 2 seconds, until reset.
If the pilot flame is lost during normal operation, the system
will try three (3) times to relight after three (3) failures, flame
loss lockout happens. The LED on the Command Center
flashes Red-Green once every 2 seconds, until reset.
Turning the master switch on the Command Center to the
off position, then ON again will reset the system.
Flame Height Control
Press the ON button (on the Command Center) once to
turn on the main burner with maximum flame height.
Press the OFF button to decrease flame height. The first
two presses will decrease the flame height to medium
and low. The third press on OFF will turn off the main
burner. In standing pilot configuration, the pilot will stay;
in intermittent pilot configuration, the pilot will be shut off.
Function
Operation
Power Up
Flip the master switch to the ON ("–")
position to power up the system
Stove ON
Press the ON s button on the Com-
mand Center or turn on wall switch to
turn the stove on
Stove OFF
Flip the master switch to the OFF ("o")
position OR press the OFF t button
3 times OR for Memory Off, hold the
OFF t button 3 seconds, or turn off
wall switch
Flame Height
Press the ON s button once to turn on
Up
the stove with maximum flame height
Flame Height
Press the OFF t button to lower the
Down
flame height to Medium and Low
Turning the Stove Off
There are three ways to turn the stove off.
1. Flip the master switch to the off ("O") position. (This
will turn the entire system OFF.)
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by
turning off the wall switch. These two commands of
OFF are (Memory Off) the system will remember all
last settings before turning off. The next time the stove
is turned on, all settings will resume. To reset, change
to the desired settings and shut off by using the Mem-
ory Off commands and the system will be reset to
those new settings.
3838
Radiance

COMMAND CENTER OPERATIONS

The following functions are available on the Command
Center.
Self Diagnostics Chart
The Command Center has a self-diagnostic LED enabling
you to troubleshoot problems and potentially avoid a service
call. Please refer to the charts below for indicator reference.
Fault
Conversion Cover
Missing
Spark Fail
No Sensor Signal
Pilot Lockout - trial
Pilot Lockout - flame
loss
Low Battery
No or Low Thermopile
Power
Learning
AC Power On
Pressure Switch Failed
(Power Vent only)
NOTE: Due to the sensitive temperature monitor-
ing components in the transmitter, it is neces-
sary to allow the transmitter to stabilize to room
temperature before accurate room temperatures
are displayed. If the transmitter is activated from
a severe cold condition, allow 15 minutes for
accurate temperature readings to appear on the
LCD display.
WARNING
Turn appliance OFF (at the Master Switch) if you are away
from your house for an extended period of time. Never
leave anything on top of the surface of the transmitter.
Function Areas of the LCD Display
Figure 59 shows the display of the TSFSC LCD.
Information Bar
The information bar shows the room temperature, the
"sending signal" radio icon, the low battery indication icon,
the child-proof icon, and the flame icon. This area doesn't
have touch buttons.
• The room temperature will always be shown after pow-
er-up. It displays the room temperature from 40 °F to
99 °F. "Lo" and "HI" will be displayed when the room
temperature is lower than 40°F or higher than 99°F, re-
spectively.
Direct Vent Gas Heater
®
LED Indication
One RED (1 time)
Two RED (1 time)
Three RED (1 time)
One GREEN, every 2 sec.
(until manual reset)
One RED-GREEN, every 2
sec. (until manual reset)
One RED, every 10s (contin-
uously)
Two RED, every 10s (contin-
uously)
GREEN Flashes, every 1
sec. (for 10 sec.)
GREEN solid
One RED every 2 sec. (until
manual reset)
20306759