Vermont Castings Radiance RADVTSCCB Installation And Operating Instructions Manual page 40

Radvt series direct vent gas heater
Hide thumbs Also See for Radiance RADVTSCCB:
Table of Contents

Advertisement

OPERATING INSTRUCTIONS
Setting Privacy Code on Transmitter
Figure 61
The remote transmitter privacy code is preset in factory.
In the event of activation or interference from other nearby
transmissions, change the code using the following pro-
cedures (learn function must be performed after changing
the code):
• Press the ON/arrow button and the
TIMER button at the same time to
enter privacy code setup mode.
• The setup display is shown in the fig-
ure. The four digits on the top stand
for the privacy code (as the actual
DIP switches on Ambient's previous
remotes). The default values of the
four digits will be all "1" (ON).
• The first digit will be flashing upon
entering the setup mode. Push the
ON button to toggle its value be-
tween "0" (OFF) and "1"(ON), and push the "OFF" but-
ton to jump to the next digit. The next digit will then start
flashing and the first one stops flashing. Set up the four
digits to your choice.
• After setting up all the four digits, push "OFF" to finish
the process and return to the previous mode.
• The Signature Command control board then needs to
re-learn the new setting.
Performing Learn Function
• The RF receiver button on the control board in the stove
must be in the ON position before the learn function can
begin. With the Command Center master switch in the
ON position, use paper clip to depress the recessed
button on Control Board, one beep for RF receiver ON or
two beeps for RF receiver OFF. Figure 62
• Holding the OFF button on the Command Center while
turning on the master switch will activate the learn
function for the transmitter. Figure 62
• After the above operation, two beeps will be given and
the green LED on the Command Center will flash for 10
seconds.
• During the 10 seconds, press the OFF button on the
transmitter to learn. Another two beeps will be given to
confirm a successful learning. Figure 63
Resetting the Transmitter
If the transmitter is not working properly, reinstall the bat-
teries to reset the transmitter.
• Pull out at least one of the batteries.
• Press any key on the screen to discharge.
• Wait for 10 seconds and reinstall the batteries.
Pushing and holding any key for more than 10 seconds
until the display refreshes will also reset the transmitter.
4040
OFF
RF Receiver
ON/OFF
Figure 61
FP2649
set privace code
FUNCTIONS AND OPERATIONS
General
The TSFSC Remote Control has four (4) operating modes:
Manual, Timer, Thermostatic and Smart Mode® thermo-
stat. The control system can be set to temperature range
between 45° F and 90° F. The blower speed and flame
height can be adjusted in the manual, timer and thermo-
static mode. The Smart Mode® thermostat will automat-
ically adjust flame height and blower speed according to
the difference between Set and Room temperatures.
The transmitter will operate the remote receiver from 1 foot
to a maximum of 30 feet. The distance is reduced when
batteries are low.
Manual Mode
Figure 63
In this mode, the TIMER button and the THERMO button
will only display "TIMER" and "THERMO", respectively with-
out showing the time and the SET temperature. Pressing
the ON/up and OFF/down buttons will change the flame
height if none of the menu buttons (TIMER, THERMO,
LIGHT, FAN, AUX) are pressed and flashing.
• Press the ON/up button to turn on the stove. The flame
icon on the LCD displays High.
Radiance
®
ON
Master Switch
LED
Battery Door
CONTROL
BOARD
FP1917
Figure 62 Command center
and control board
Signature components
8/08
Do not use two (2) or more remote control
systems in the same area with the same privacy
code setting, as they will communicate with
each other. This may cause the appliances to
malfunction.
Direct Vent Gas Heater
FP1917
Front Panel Bezel
Optional
FP2650
command ctr ctrl brd
20306759

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents