BURNER, PILOT AND CONTROL
COMPARTMENT
WARNING
Turn off gas before servicing stove. It is recommended
that a qualified service technician perform these check-
ups at the beginning of each heating season
Keep the control compartment, stones and burner areas
surrounding the stones clean by vacuuming or brushing
at least twice a year. Make sure the burner porting, pilot
air opening and burner air opening are free of obstructions
at all times.
Pilot Flame
The flames from the pilot should be visually checked as
soon as the heater is installed and periodically during
normal operation. The pilot flame must always be present
when the stove is in operation. Figure 71. The pilot flame
has three distinct flames, one engulfing the sensor, one
engulfing the thermopile, and the other reaching to the
main burner.
Burner
Inspect area around the injector. Remove any lint or foreign
material with a brush or vacuum.
Burner Flame
The flames from the burner should be visually checked
as soon as the heater is installed and periodically during
normal operation. In normal operation, at full rate, and after
operating for about 15 to 30 minutes, the flame should be
yellow.
If the flame is blue and candle-like in appearance, adjust
glass or add more glass over ports.
NOTE: The type of installation, vent system con-
figuration, and wind effects may cause the flame
patterns to vary.
20306759
Fig.71 Pilot Flame
FP2453
hooded pilot flames
TROUBLESHOOTING
Sensor
Thermopile
FP2453
45