Vermont Castings Radiance RADVTSCCB Installation And Operating Instructions Manual page 47

Radvt series direct vent gas heater
Hide thumbs Also See for Radiance RADVTSCCB:
Table of Contents

Advertisement

Radiance
Direct Vent Gas Heater
®
8. Verify that if the conversion is from NG to LP, the screw
must be reassembled with the red o-ring visible. (Fig-
ure 77)
9. Replace the black protection cap.
LP Configuration
Red O-ring Visible
Red O-ring NOT Visible
Fig. 77
NOTE: Check that also the pilot and main burner
injectors are appropriate for the gas type.
CO141
Pilot Orifice Conversion
O-ring configuration
• Locate pilot. (Figure 78)
6/07
• Replace pilot orifice.
• Remove pilot hood by lifting up. (Figure 79) Do not re-
move the snap ring to remove the pilot hood.
NOTE: It is not necessary to remove the pilot tube
for conversion.
• Remove pilot orifice with Allen wrench. (Figure 80)
• Install the conversion orifice.
Fig. 78 Locate pilot.
Pilot hood
ST350
Jefferson
air shutter adj
3/20/00 djt
Pilot bracket
Fig. 79 Remove pilot hood.
20306759
Natural Gas
Configuration
Pilot
CO105a
Index tab
Snap ring
CO141
Fig. 80 Remove pilot orifice.
• Reinstall pilot hood. Be sure to align hood with index
tab.
ST916
FUEL CONVERSION
Allen wrench
CO106a
DV360/580
Gas Conversion
Pilot2
1/28/00 djt