FUEL CONVERSION

WARNING
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing
property damage, personal injury or loss of life. The
qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and
complete until the operation of the converted appliance
is checked as specified in the manufacturer's instruc-
tions supplied with the kit.
CAUTION
The gas supply shall be shut off prior to disconnecting
the electrical power, before proceeding with the conver-
sion (Figure 72).
Gas Supply Inlet
Fig. 72 Attach the gas line to the right side of the valve.
CONVERSION PRECAUTIONS
ST226
Before proceeding, turn control knob on valve to OFF and
attach gas line
turn gas supply OFF. Turn OFF any electricity that may be
12/8/99 djt
going to the appliance.
CONVERSION PROCEDURE
• Remove stove front. Lift stove front up and then swing
bottom out and away to disengage from the stove body.
• Undo the right and left latches at the top of the glass
frame.
• Pull the top edge of the glass and frame assembly away
from the firebox face. Place the assembly out of the
way on a flat, padded surface such as a counter pro-
tected by a towel.
• Remove the logset from the firebox.
4646
VALVE CONVERSION
RADVT Series Models (Millivolt)
• Turn control knob to the OFF position, and shut off the
• Allow the valve to cool to room temperature.
• Remove the black protection cap by hand. (Figure 73)
Fig. 73
• Insert a 5/32" or 4 mm Allen wrench into the hexagonal
• Check that the screw is clean and if necessary remove
• Using the Allen wrench as shown in Figure 76, rotate
Main
Shut
Gas
off
Line
Valve
ST226a
Fig. 75
Radiance
gas supply to the valve.
Fig. 74
CO138
remove screw
6/07
key-way of the screw (Figure 74), rotate it counterclock-
wise until it is free and extract it.
dirt. Flip the screw. (Figure 75)
the screw clockwise and tighten until snug.
NOTE: Do not over-tighten the screw. Recom-
mended to grip the wrench by the short side.
CO140
turn screw
6/07
Direct Vent Gas Heater
®
CO139
Allen wrench
6/07
Fig. 76
CO139
Allen wrench
6/07
20306759