Vermont Castings Radiance RADVT Series Installation & Operating Manual

Vermont Castings Radiance RADVT Series Installation & Operating Manual

Direct vent gas heater

Advertisement

Installation & Operating Manual
Installation and Appliance Setup - Care and Operation
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
NOTICE: SAVE THESE INSTRUCTIONS
RADVT Series Radiance®
Direct Vent Gas Heater
Models:
RADVT-IFT-BD, RADVT-IFT-BM,
RADVT-IFT-BS, RADVT-IFT-CB,
RADVTCBSB, RADVTBSSB, RADVTBDSB,
RADVTBMSB
CERTIFIED
S
B
AFETY
ARRIER
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
11
12697
Radiance cover
7/07
Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death or property damage.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use
any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
– If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and shall be installed.
DANGER
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Un panneau vitré chaud peut
causer des brûlures.
Laissez refroidir le panneau
3-90-30007498
vitré avant d'y toucher.
Ne laisser jamais les enfants

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings Radiance RADVT Series

  • Page 1 DANGER Un panneau vitré chaud peut causer des brûlures. Laissez refroidir le panneau Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498 vitré avant d’y toucher. Ne laisser jamais les enfants...
  • Page 2: Table Of Contents

    PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    Wiring errors can cause improper and dangerous (mobile) home, where not prohibited by state or local codes. operation. Verify proper operation after servicing. * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer. Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 4: Massachusetts Safety Information

    248 CMR 5.08(2)(a)1 through 4. Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 5: Framing And Clearances

    R A D I A N C E 28" (711 mm) Supply Inlet 5" (127 mm) 18-1/4" 31" (464 mm) (787 mm) Weight: Fully assembled; 350 lbs. Figure 2.1 - Radiance dimensions. Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 6: Installation Requirements

    This appliance is for use only with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 7: Hearth Requirements

    9/28/00 djt Sidewall Clearance 6” (150 mm) *Needed for installing DuraVent Minimum Vent Kit #2792 or HHT Minimum Vent Kit #SLP-FSSK. Figure 2.6 - Dimensions and clearances to ceiling or alcove. Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 8: Gas Specifications

    Refer to this manual for correct installation and operational pro- cedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 9 Horizontal Run (in feet) **No Restrictor Plate of screw to of screw to Figure 2.8 - Vertical vent termination window. top edge of top edge of plate plate Figure 2.10 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 10 For installations using DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Horizontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures. 1010 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 11: Chimney Diagram

     Only permitted if veranda, porch, deck or balcony is fully open requirements. on a minimum 2 sides beneath the floor. 1111 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 12 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap. Figure 2.12 - Termination clearances. 1212 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 13: Assembly And Installation

    1-1/2” (37mm) less than the nominal dimension; i.e., a 6” *CCSLP adapter is required when using HHT components. (152 mm) Straight pipe section has an effective length of 4-1/2” (115 mm). 1313 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 14: Assembling The Stove

    Read all instructions before starting installation, then follow these instructions carefully to maximize stove performance and safety. Report damaged parts to your dealer. 1414 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 15 Items required for installation: Tools: Phillips screwdriver Hammer Saw and/or saber saw Level Measuring Tape Electric drill and bits Pliers Square Building Supplies: Framing materials Wall finishing materials Caulking Material (noncombustible) 1515 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 16 If slip section seals are broken during removal of the termination cap, vent may leak. CORRECT INCORRECT Figure 3.3 - Make sure the seams are not aligned to prevent unintentional disconnection. 1616 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 17 Figure 3.8 - Rotate Seams for Disassembly edges of cap. When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149 installation codes. 1717 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 18 2” (51 mm) (or the distance required if installing a second 90° elbow), Figure 3.13. NOTE: Always install vertical side wall horizontal venting with a 1/4” rise for every 12” of run. 1818 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 19 Figure 3.15 - Use extension brackets to mount snorkel against recessed wall. Termination Cap Figure 3.14 - Horizontal Termination Cap on a Vinyl Siding Wall SLP Cap ST219 snorkel detail 12/6/99 djt 1919 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 20 • The maximum angular variation allowed in the system is 270°, Figure 3.18 ST933 • For the minimum height of the vent above the highest point of penetration through the roof, Figure 3.18. Selkirk vertical venting 6/07 2020 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 21: Log Set Installation

    être installé. Figure 3.21 - Rear Log Figure 3.19 - Remove the safety barrier and stove front. LG488 rear log ST139 6/07 Radiance remove front 4/20/01 djt 2121 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 22: Thermostat Connection

    Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation. Ember Bed Front Left Log Figure 3.24 - Completed Installation LG490 all logs 6/07 2222 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 23 Conversion Kit. To convert from Natural Gas to LP use Kit #20012729 or #SRV30007495. To convert from LP to Natural Gas use Kit #20012899 or #SRV30007496. Conversion instructions are provided with each kit and in this manual. 2323 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 24: Radvt-Ift Wiring Requirements

    IFT-RC400 REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 3.26 - RADVT-IFT Wiring Diagram 2424 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 25: Fuel Conversion

    A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed. DANGER 2525 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498 Un panneau vitré chaud peut causer des brûlures.
  • Page 26: Operating Instructions

    Turn clockwise counterclockwise to decrease to increase flame height flame height CO105d Figure 4.3 - Flame adjustment knob for SIT valve. Pilot flame FP390 6/07 djt FLAME ADJUSTMENT KNOB 11/21/96 2626 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 27: Lighting And Operating Instructions

    4. Push in gas control knob slightly and turn clockwise 2. Turn off all electric power to the stove if service is to be to “OFF". Do not force. performed. 5. Close control access panel. 2727 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 28: Troubleshooting

    (high) causing and thermocouple. the pilot safety to drop out 2. Possible blockage of the 2. Check the vent terminal for blockage (recycling the flue gases) vent terminal 2828 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 29: Read Before Lighting

    D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water. 2929 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 30: Lighting Instructions (Ift)

    For additional information on operating your Keep burner and control compartment clean. See installation and operating instructions Hearth & Home Technologies fi replace, please 593-913J accompanying appliance. refer to www.hearthnhome.com. 3030 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 31: Operation During A Power Outage - Intellifire

    • Slide the ON/REMOTE/OFF switch to the ON position NOTICE: Some functionality will be lost when using battery backup including remote control, fan, lights, or any other auxiliary functions that require household 110-120 VAC power 3131 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 32: Detailed Component Operating Instructions Intellifireā„¢ Touch

    2. If multiple control options are installed, the IFT-ECM will respond to the last command from the wired wall switch or IFT-RC400. The wired wall switch is NOT available if a Power Vent is used. 3232 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 33 • ON/OFF Functions • Flame height adjustments • Thermostat • Cold Climate Feature • Fan Speed Please refer to the instructions included with the remote control for more detailed operating instructions. 3333 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 34: Intellifire Tm Touch Controls

    Verify home circuit breaker is on and master reset is on (if No power to appliance. equipped). remote displays following message on-screen: “Remote Control Communication Error.” Power outage. Install new batteries in battery backup. 3434 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 35: Troubleshooting

    40 ohms. If open or shorted, replace valve. Check valve harness wire continuity, if open replace 6-pin harness. Pilot won’t light, there is no noise or spark, Spark coil failure. Replace ECM. 2 Red/2 Green Lockout. 3535 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 36 Damaged pilot assembly. Check resistance between tip of sense rod and IFT-ECM connector, should be less than 1 ohm. Replace pilot assembly if damage is detected. 3636 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 37: Burner, Pilot & Control Compartment

    If the flame is blue and candle-like in appearance, adjust glass or add more glass over ports. NOTE: The type of installation, vent system configuration, CO105d and wind effects may cause the flame patterns to vary. Figure 4.6 - Correct pilot and burner flame appearance. Pilot flame 6/07 djt 3737 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 38: Cleaning And Maintenance

    Une barrière visant à réduire le risque de brûlure Turn the pilot off before painting. Allow the heater to cool par le hublot chaude est fournie avec cet completely before painting. appareil et doit être installé. 3838 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 39: Glass Replacement

    Figure 5.2 - Release the latches to remove the glass frame. Do not use your stove if the flame pattern differs from that F. Gasket Replacement shown here. Contact your Vermont Castings dealer or a S T141 pull glass latch qualified technician for help.
  • Page 40: Wiring Diagrams

    Chassis Ground wiring 1/11/00 djt Optional Blower Kit Schematic Diagram MOTOR ST153 rdv connections diag. 10/99 SNAPSTAT ON/OFF RHEOSTAT Figure 6.2 - Fan circuit. ST236 FK26 wiring diagram 12/99 4040 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 41 SENSE REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 6.3 - RADVT-IFT Wiring Diagram 4141 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 42: Service Parts List

    Direct Vent Gas Heater Ending Manufacturing Date: Active With Standing Pilot Ignition RADVTCBSB (Classic Black) RADVTBMSB (Majolica Brown) RADVTBDSB (Bordeaux) RADVTBSSB (Biscuit) Part number list on following page. 03/19 4242 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 43 Classic Black 30001751A Biscuit 30003239A Left End Bordeaux 30006789A Brown Majolica 30004927A Classic Black 30001752A Biscuit 30003238A Right End Bordeaux 30006788A Brown Majolica 30004926A Additional service parts on following page 4343 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 44 Wire w/Straight Term 2 End, 50” 1002582 Gasket, Base Pan 20004287 Gasket, HE Door 1203687A Gasket Cement, 3 oz. Tube 1206122 Restrictor Plate 20013028 Additional service parts on following page 4444 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 45 Touch-Up Paint Bordeaux 0001341 Majolica 0001270 Control Plate Assembly (Valve, Burner, Pilot) RADVT - NG 20012208 Conversion Kits Conversion Kit, NG to LP 20012729 Conversion Kit, LP to NG 20012899 4545 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 46 Beginning Manufacturing Date: Feb 2019 Ending Manufacturing Date: Active Direct Vent Gas Heater w/IFT Controls RADVT-IFT-CB (Classic Black) RADVT-IFT-BM (Majolica Brown) RADVT-IFT-BD (Bordeaux) RADVT-IFT-BS (Biscuit) Part number list on following page. 03/19 4646 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 47 Classic Black 30001751A Biscuit 30003239A Left End Bordeaux 30006789A Brown Majolica 30004927A Classic Black 30001752A Biscuit 30003238A Right End Bordeaux 30006788A Brown Majolica 30004926A Additional service parts on following page 4747 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 48 2326-130 Module, B Type AC 2326-150 Transformer, 6 Volt Wall SRV2326-131 Wire w/Straight Term SRV30007499 Trim, On/Off Switch 30000874 Tie Bracket Assembly 20012442 Additional service parts on following page 4848 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 49 SRV30007495 Conversion Kit Propane to NG SRV30007496 NGK-DXV-50 Regulator SRVLPK-DXV-50 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 3A fuse, 3/4” long 4949 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 50: Optional Accessories

    2. Position the shelf and adjust the brackets so the shelf RCB,RCMT TSST, RCST fits correctly. 3. Tighten the screws. Refer to the instructions included with each warming shelf for complete installation procedures. 5050 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 51: Warranty Policy

    Firebox and heat exchanger, Grate and Stainless Limited 3 years Steel Burners, FlexBurn® System (engine, inner Lifetime cover,access cover and fireback) 90 Days All replacement parts beyond warranty period 5151 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498 4021-645J • 08-03-17...
  • Page 52 Consideration must be given to the appliance location and configuration, environmental conditions, insulation and air tightness of the structure. 4021-645J • 08-03-17 5252 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 53 EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645J • 08-03-17 5353 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...
  • Page 54 Based on CSA P.4.1-2015 EFFICIENCY RATINGS ENERGUIDE RATINGS D.O.E. STOVE EFFICIENCY MODEL PERCENTAGE (AFUE PERCENTAGE) RADVT Series 62.7 68.4 RADVT-IFT Series 66.2 68.4 352 Mountain House Road • Halifax, PA 17032 www.vermontcastings.com 5454 Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19 3-90-30007498...

Table of Contents