Take care when combining multiple schedules and actions as troubleshooting
can get confusing. Always check and test functionality a single step at a time.
Remember that Users and Zones have multiple levels of permissions, check that
when a higher level permission is not active, whether the lower level permission
is still appropriate at all times.
Example
When a certain user is in the building we can prevent an automatic Arm-Disarm
from occurring.
First program an Action with the conditions you want and the Duration of the
Action if necessary.
Next program Arm-Disarm with a User and Schedule.
Then set the Schedule to Follow Action Number.
When the action events are met, then the Schedule will become active and will
be able to perform an Arm-Disarm at the appropriate time. If the conditions are
not met then the Arm-Disarm will never occur.

Programming Instructions for Speech Tokens

Goal
Customize the spoken names of zones, Partitions, and outputs.
Pre-conditions
None
Notes
Refer to Speech Token Library in the Appendix for a list of available words and
the corresponding token number.
Instructions
1. Select Zone Tokens, Partition Tokens, Output Tokens, or Room Tokens.
2. Select the item number you want to customize.
3. Determine the name of the item using up to eight (8) of the words available in
the library.
4. Enter the corresponding token numbers into each of the slots.
5. Test the new spoken name to ensure it is what you want.
Example
1. We want Zone 1 to be announced as "Front Office Motion Zone".
2. Look up each of these words in the Speech Token Library in the Appendix.
We get 68, 106, 102, 122.
3. Go to the Speech Tokens menu, select Zone Tokens, select Zone 1.
116