NXG-003 xGen Metal Enclosure

A spare metal enclosure is available for those installations where additional xGen
zone and/or output expanders are required or in case a larger backup battery is
required. The xGen NXG-003 metal enclosure includes a tamper switch and one
metal DIN rail. A second metal DIN rail (NXG-003-DIN) can be added if required
but in that case a backup battery of max 12 VDC / 7 Ah will fit the enclosure.
The enclosure should be installed in accordance with EN50131-1 Environmental
Class II to provide operating conditions within:
Temperature range: -10 to +55°C.
Humidity range: Average 93% relative humidity, non-condensing
To install a module, release the locking tab(s) and place on the DIN rail then
push the locking tab(s) to secure the module. To remove a module, use a small
flat-blade screwdriver to release the locking tab(s) on the xGen module then
remove from the DIN rail. Refer to module installation manual for further details.

Power Requirements

The xGen intrusion panel family is designed to be used with a 40 VA TD300-
E101F transformer (p/n NXG-003-X) which is included in the xGen panel. This
transformer includes a 500 mA 250 VAC fast blow replaceable fuse on the
terminal block.