J8 – Terminals for future use
J11 – Terminals for Zone 1 and 2
J15 – Terminals for Zone 3 and 4
J17 – Terminals for Zone 5 and 6
J19 – Terminals for Zone 7 and 8, can be configured to become Output 5

xGen LED Indicator Diagram

LEDs Top Row (left to right)
D3 Red LED – 5 V internal power present
D5 Red LED
Enrollment mode active, slow flash means Automatic enrollment, fast flash
means Manual enrollment
During a default it will toggle during each menu default
When communicating over the phone line it will turn on when a valid
handshake tone or kiss off tone is present
During a phone session it will turn on when a DTMF digit is detected
D10 Red LED – follows Output 1 (BELL output), typically used for indoor
speaker
xGen Installation & Programming Guide
17