Waterflow Delay
Ref #: [00020311]
This delay is to prevent false alarms due to surges in the
sprinkler system. The Maximum delay allowed is 90 sec-
onds. The default is 000 seconds (disabled). The Water-
flow Delay must be 90 seconds or less. This delay affects
all zones programmed as Waterflow, zone type (10). See
5.4 'Zone Programming'.

10.10 Cross Zone (Police Code) Alarm

Ref#: [00020301] Police Code Timer
Ref#: [00040307] Cross Zone (Police Code) reporting code
The Cross Zone (Police Code) reporting code will be trans-
mitted when two different zones on the same partition go
into alarm within the Police Code Time. When the first
zone goes into alarm, the panel will send the alarm report-
ing code and will start the Police Code Timer.
If a second zone goes into alarm before the timer expires,
the panel will send the second zone alarm and the Cross
Zone (Police Code) reporting code.
Valid entries for the Police Code Timer are from 000-255
minutes. The default setting is 060.
NOTE: For UL listed systems, crossed zones shall overlap
100% in the protection area.

10.11 System Label

Ref #: [0009]
This section allows you to program a label for the secu-
rity system. The label will be used to log events that do
not pertain to any partition (e.g. AC trouble). Program a
label up to 14 characters long. Enter each character as
outlined in 'Programming System Labels'.

10.12 Hourly Print

Ref #: [000200]
Enable this option to have the system print 'Hourly
Printer Test', and the time and date every hour.