1.7 Bypassing Zones

You can use zone bypassing when access is needed to part of the protected
area while the system is armed. Zones which are temporarily out of service
due to damaged wiring or contacts may be bypassed to allow system
arming until repairs can be made.
Bypassed zones will not cause an alarm. Zones cannot be bypassed once
the system is armed. Bypassed zones are automatically canceled each time
the system is disarmed and must be reapplied before the next arming.
NOTE: For security reasons, your system administrator may program
the system to prevent you from bypassing certain zones.
Bypassing zones reduces your security protection. If you are bypassing a
zone due to damaged wiring or contacts, please notify your system
administrator or call a service technician immediately so that the problem
can be resolved and your system returned to proper working order.
To bypass zones:
1. Enter [
2. A menu will outline the various bypassing options. Use the arrow (<
>) keys to scroll through the options. When you find the correct
option, press the [
number in parentheses. The bypassing options are as follows:
[0] Bypass Open Zones – This section will only display the zones which
[0] Bypass Open Zones
[0] Bypass Open Zones
[0] Bypass Open Zones
[0] Bypass Open Zones
are currently open or bypassed. Use the arrow (< >) keys to scroll through
these zones. Zones that are open will be indicated by an exclamation (!)
mark in the lower right hand side of the keypad display. To select a zone
to be bypassed, press the [
to indicate that the zone has been bypassed. When you are done selecting
zones, press [#] to exit.
[1] Bypass Zones
[1] Bypass Zones – This selection takes you immediately to bypassing
[1] Bypass Zones
[1] Bypass Zones
[1] Bypass Zones
zones. Use the arrow (< >) keys to find the zone to be bypassed and press
the [
*
] key to select it. A "
that the zone has been bypassed. When you are done selecting zones,
press [#] to exit.
[2] Clear Bypasses
[2] Clear Bypasses
[2] Clear Bypasses
[2] Clear Bypasses – This selection will allow you to turn bypassing off
[2] Clear Bypasses
for all of the zones in your partition.
[3] Recall Bypasses
[3] Recall Bypasses – This selection will automatically bypass the same
[3] Recall Bypasses
[3] Recall Bypasses
[3] Recall Bypasses
group of zones which were bypassed the last time the partition was armed.
[4] Pr
[4] Pr
evious Menu
evious Menu
[4] Previous Menu
[4] Pr
[4] Pr
evious Menu – This selection will return the display to "Enter Code
evious Menu
to Arm System." From here, you will be able to arm the system.
S e c t i o n
*
] [1]. You may be required to enter your access code.
*
] key to select it, or press the corresponding
*
] key. A "
*
" will appear next to the zone label to indicate
1 :
G e n e r a l
S y s t e m
*
" will appear next to the zone label
O p e r a t i o n
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxsys pc4020Maxsys pc4020 - v3.3

Table of Contents