S e c t i o n 8 : A r m i n g a n d D i s a r m i n g

8.1 Arming and Disarming Options

Ref #: [0100XX01] where XX = Partition 01-08
The following arming and disarming options are pro-
grammed by partition.
If the Bell Squawk option is enabled, outputs will activate
once briefly when the partition is armed and twice when
the partition is disarmed. All outputs programmed for 'Fire
and Burg,' 'Inv Fire/Burg,' 'Burg Only' or 'Inv Burg Only'
will squawk (default=No).
In an attempt to reduce false alarms, the Audible Exit Fault
( Aud. Exit Fault ) toggle option is designed to notify the user
of an improper exit when arming the system. In the event
that the user fails to close the exit/entry door properly, the
system will notify them in two ways: the keypad will emit
one continuous beep and the burglary bell outputs will acti-
vate. If this occurs, the user must re-enter the premises,
enter their access code to disarm the system, and then fol-
low the arming procedure again (default=No).

8.2 Automatic Arming

Automatic system arming is accessible by the user or sys-
tem administrator through the [*][6] System Functions
Menu. Through this menu, the user can set auto arm times,
days, select a programmed auto arm or disarm schedule
and turn auto-arming on and off.
NOTE: If the system has a Loss of Time trouble, automatic
arming and disarming will not work.
For more information regarding automatic arming, please
see the Instruction Manual 'Auto Arm Control'.
To program auto-arming schedules for partitions, see 14.4
'Arming/Disarming Schedules'.
Auto-arming Options
Ref #: [0100XX01] where XX = Partition 01-08
Automatic arming is enabled or disabled for each partition.
If the Auto Arm/Disarm partition toggle option is enabled
for a selected partition, the user will be able to set up auto-
arming for that partition (default=Yes).
If the Autoarm Req Code toggle option is enabled, the user
must enter an access code during the auto arm pre-alert
period in order to prevent arming. If disabled, pressing any
key will cancel auto-arming. The Auto-arm Cancellation
reporting code, if programmed, will be sent in either case
(default=No).
If Autoarm Squawk toggle option is enabled, the bell output
will squawk for one second every 10 seconds during the
auto arm pre-alert period. If disabled, the bell will not
sound (default=No).
NOTE: Auto-arming shall not be used on UL listed systems.
Auto-Arm Pre-Alert Period
Ref#: [0100XX0205] where XX = Partition 01-08
When a partition begins auto-arming, all keypads assigned
to that partition will sound steady for the programmed pre-
alert period. During this time, the partition is not armed
and a user can postpone/cancel auto-arming by pressing
any key on a partition keypad, or entering their access code,
if required. The pre-alert period time can be programmed
from 001 to 255 minutes (default = 001).
28
Postpone Arm
Ref #: [00020305]
If the Postpone Arm time is programmed, the user will not be
able to cancel the auto-arm sequence. The user will only be
able to postpone auto-arming for the programmed amount
of time by pressing a key or entering their access code. Once
the timer expires, the auto-arming sequence will begin again.
Auto-arming can be postponed multiple times. The panel
will continue to attempt auto-arming until it is successful.
NOTE: Disabling the auto-arming feature using the [*][6]
command will not cancel auto-arming once the auto-arm-
ing sequence has begun.
Valid entries for the Postpone Arm time are from 000 to
255 minutes. The default setting is 000 (postpone auto-
arming disabled).

8.3 Close Time Timer (CTT Duration)

Ref#: [0100xx0208] where XX = Partition 01-08
This will be a time entry from 000-255 minutes (000 disables
the feature) that will be multiplied by 5 minutes to produce
the timer value (lets call this time T). This feature is to be
used in conjunction with the Event Scheduling 'CTT Sched-
ule' (see section 14.6).
• When a partition is disarmed and the CTT Schedule is
active, the timer will start.
• At T-15 keypads belonging to the partition will beep
once every four seconds and a message will display
"Arming In Progress" (this message will function as the
Date & time display does: pressing pound will cause
base mode to be displayed and the message will re-
appear after 10 seconds of no key presses)
• At T-5 will beep twice every four seconds (urgency)
• At T-1 the partition will begin a normal auto arm proce-
dure (all auto-arming features will be followed).
• When T is reached the partition will arm. This will be
logged and transmitted as a normal auto arm.
• If the schedule has expired and the system is in the pro-
cess of CTT arming, the system will continue to count
down until a code is entered or the arming occurs.
If a valid access code with the disarm bit set is entered after
T-15 but before the partition arms (anytime during the CTT
pre-alert) the access code used will be logged to the event
buffer using a "User Log" and T will be set to 1 hour (the
process will begin again). If the code is entered during the
auto arm pre-alert the 'auto arm abort' logs will be gener-
ated. If the partition is armed everything will be reset until
the next disarming.
For the CTT arming feature to function properly on a parti-
tion the Auto arm Abort Required Code option for that par-
tition must be enabled (the option is disabled by default).
The default for this timer should be 000.
NOTE: Close Time Timer not to be used with UL Listed
Installations.

8.4 Disarm Delay

Ref#: [0100xx0209] where XX = Partition 01-08
If the Disarm Delay is programmed and the user who
entered their access code to disarm has the user code option
(see Section 7.5) Disarm Delay enabled, the partition will
NOT disarm immediately. The keypad will display " Dis-
arming in XXX Minute(s)" where XXX is the Disarm delay
time. This feature should only be used on an area which has
an automatic lock on the entry point, which unlocks on the
disarm sequence.