S e c t i o n 5 : P a r t i t i o n s a n d Z o n e s

5.1 Zone Supervision

Ref # [000204] 'Zone Supervision'
The control panel must be instructed to supervise either No
End of Line, Single EOL or Double EOL zone loops. These
three options are described in Section 2.5 'Zone Wiring'.
To program this option, perform the following:
1. Enter installer's programming by pressing [*] [8]
[Installer's Code].
2. Enter reference number [000204] and press [*].
3. Scroll through the three supervision types. Press [*] to
select the supervision type you require.

5.2 Creating Partitions

Once all system wiring has been completed and you have
enrolled your keypads and modules, you can begin pro-
gramming partitions. This will include indicating the num-
ber of partitions and programming the available options for
each. Partitions must be programmed individually.
NOTE: If you do not wish to use partitions, you must assign
all zones which will be used to Partition 1 (see 5.3 'Adding
Zones to Partitions').
There are five basic programming items for each partition:
1. Programming the partition account number.
2. Programming the partition toggle options.
3. Programming the partition times (entry and exit delay
times, etc.).
4. Adding zones to the partition and defining each zone
(zone label, zone type and attributes).
5. Programming the partition label.
Partition Account Number
Ref #: [0100XX00] where XX = partition number
Enter a 4 or 6-digit partition account number. Partitions can
all report using the same account number, or each can be pro-
grammed differently depending on your application. Enter
the four or six digits and record them into your Program-
ming Worksheets . Once you have entered all the digits, the
display will return to the 'Partition Acct #' prompt.
Partition Toggle Options
Ref #: [0100XX01] where XX = partition number
There are numerous partition options which can be either
enabled (select 'Y' for yes) or disabled (select 'N' for no).
Pressing [*] will toggle between the yes and no options.
The following partition toggle options generally pertain to
the operation of the keypads, the entry and exit delay
options and the end user feature accessibility for the
selected partition. These features are explained in detail in
other sections of the manual. Below is a list of the available
options followed by their default. Each option is described
later in this manual in the specified sections.
[F] Enabled (Y)........................... see section 6.5 on page 20
[A] Enabled (Y).......................... see section 6.5 on page 20
[P] Enabled (Y) .......................... see section 6.5 on page 20
Display Clock (Y) ...................... see section 6.1 on page 19
Clock Armed (N)....................... see section 6.1 on page 19
Disp Exit Time (Y)..................... see section 6.1 on page 19
Bypas Req Code (Y) .................. see section 7.9 on page 26
AutoArm/Disarm (Y) .............. see section 8.2 on page 28
Autoarm Req Code (N) ............ see section 8.2 on page 28
Autoarm Squawk (N)............... see section 8.2 on page 28
Bell Squawk (N) ........................ see section 8.1 on page 28
Keypad Lockout? (N) ............... see section 6.6 on page 20
Cmd. OutX Req Cd (N)............ see section 7.9 on page 26
[*][6] Any Cd (N) .......................see section 7.9 on page 26
Exit Delay Aud (N)....................see section 9.2 on page 30
Exit Delay Sqk. (N) ....................see section 9.2 on page 30
Aud. Exit Fault (N)....................see section 8.1 on page 28
Entry Urgency (N) .....................see section 9.2 on page 30
Entry Squawk (N)......................see section 9.2 on page 30
Exit Del. Term (N)......................see section 9.2 on page 30
System Alarms (N) ....................see section 6.1 on page 19
System Status (N) ......................see section 6.1 on page 19
Sen. Rst. Cmd#2 (Y).................see section 11.3 on page 34
Spcl Alm Entry (Y) ....................see section 9.2 on page 30
Exit Tbl Beep (N) ......................see section 9.2 on page 30
Dual Usr Dis (N)........................see section 8.5 on page 29
No-Act Grp Byp (N)..................see section 5.5 on page 17
Partition Times
Ref #: [0100XX02] where XX = partition number
There are 11 different partition times to be programmed.
See the corresponding section for further information
regarding each timer:
• Entry Delay – section 9.1 'Entry and Exit Delay Times'
• Exit Delay – section 9.1 'Entry and Exit Delay Times'
• Auxiliary Entry Delay – section 9.1 'Entry and Exit
Delay Times'
• Auxiliary Exit Delay – section 9.1 'Entry and Exit Delay
Times'
• Delinquency – a Closing Delinquency reporting code
will be sent if the partition is not armed for the number
of days programmed in this section.
• Autoarm Pre-alert – section 8.2 'Automatic Arming'
• Quick Bypass Duration - '24Hr Quick Bypass (24)'
• Quick Bypass Pre-alert - '24Hr Quick Bypass (24)'
• Close Time Time Duration - see Section 8.3
• Disarm Delay Timer - see Section 8.4
• Group Bypass Duration - see Section 5.5
Three digits are required for each entry.
Zone Assignment
Ref #: [0100XX03] where XX = partition number
This procedure is outlined in Section 5.3 'Adding Zones to
Partitions'.
Partition Labels
Ref #: [0100XX04] where XX = partition number
Program partition labels in this section. All system display
labels are programmed in a similar fashion. For instructions
on programming labels, see 5.4 'Zone Programming'.
Deleting Partitions
Ref #: [0101]
Scroll to the partition to be deleted, then press [*]. When a
partition is deleted, the programming assigned to it will not
be erased. If the partition is re-enabled, the programming
that was entered will still be there.
NOTE: When a partition is deleted, the zones assigned to it
are removed from the Zone Assignment.
Copying Partitions
Ref #: [0102]
Enter this section to copy the programming from one parti-
tion to another one. The programming that will be copied
includes the Customer ID Code, Partition Toggles, Partition
Times, Access Code Levels and Command Output Labels.
The zone assignment will not be copied. To copy a parti-
tion:
13

Hide quick links: