Appendix A: Reporting Codes - DSC MAXSYS PC4020 Installation Manual

Hide thumbs Also See for MAXSYS PC4020:
Table of Contents

Advertisement

A p p e nd ix A: Re p o rt i n g C o d e s
Notes on Contact ID
The following is a list of Contact ID reporting codes. The
first digit (in parentheses) will automatically be sent by
the control. The last two digits are programmed to indi-
cate specific information about the signal.
For example, if zone 1 is an entry/exit point, the alarm
reporting code could be programmed as [34]. The central
station would receive the following:
*BURG - ENTRY/EXIT - 1
In the above example, the "1" indicates the zone in
alarm.
Ref. #
Reporting Code
[00040300] Zone Alarms
[00040301] Zone Restorals
[00040302] Zone Trouble/Tamper
[00040303] Zone Trouble/Tamper Rest.
[00040304] Zone Fault
[00040305] Zone Fault Rest.
[00040306] [F] Key Alarm/Rest.
[00040306] [A] Key Alarm/Rest.
[00040306] [P] Key Alarm/Rest.
[00040307] Duress Alarm
[00040307] Opening After Alarm
[00040307] Recent Closing
[00040307] Cross Zone (Police Code)
Alarm
[00040307] Door Forced Alarm/Rest.
[00040307] Door Open Too Long Alarm/
Rest.
[00040308] General System Tamper/Rest.
[00040309] Keypad Lockout
[00040309] 2-wire Alarm/Rest.
[00040309] Waterflow Alarm/Rest.
[00040309] 2-wire Trouble/Rest.
[00040309] Waterflow Trouble/Rest.
[00040309] Fire Test Begin
[00040309] Fire Test End
[00040309] Fire Bypass/Unbypass
[00040310] Closings
42
Code Sent When...
zone goes into alarm
alarm condition has been restored
zone exhibits a trouble/tamper condition
trouble/tamper condition has cleared
zone exhibits a zone fault
zone fault condition has cleared
Keypad fire alarm (alarm and restore rep.
codes sent together)
Keypad auxiliary alarm (alarm and restore rep.
codes sent together)
Keypad panic alarm (alarm and restore rep.
codes sent together)
Duress code entered
partition disarmed with alarm in memory
alarm occurs within two minutes of partition
arming
two zones on the same partition go into
alarm within the Police Code Time during any
given armed period (incl. 24Hr zones)
access control door forced open alarm event
(PC4820 only)
access control door open too long events
(PC4820 only)
enrolled module with tamper inputs has a
tamper alarm
max. number of incorrect access codes has
been entered at a keypad
2-wire smoke alarm (PC4701 only)
waterflow zone alarm (PC4701 only)
2-wire smoke zone has a trouble (open) condi-
tion (PC4701 only)
waterflow zone has trouble (open) condition
(PC4701 only)
fire inspector's test start & fire drill test begins
fire inspector's test end & fire drill test ends
fire zone bypassed/unbypassed
partition armed (user 001-128 indicated)
** PPP = partition number; UUU = user number (user 1000=999); ZZZ = zone number
Notes on SIA Format
If the SIA 1 Account # option is selected, the panel will
send the system account code along with its data trans-
mission (ref # [000401], scroll to option). At the receiver,
the transmission would look similar to this example:
N Ri01
/ BA 001
N
= New Event
Ri01
= Partition /Area Identifier
BA
= Burglary Alarm
001
= Zone 1
Dialer
Direction*
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
O
O
A/R
A/R
A/R
A/R
A/R
A/R
A/R
O/C
* A/R = alarms/restorals; O/C = openings/closings; O = other
Contact
SIA Auto Rep
ID
Codes**
see Appendix B "Zone
Reporting Codes"
(1) 15
FA-000/FH-000
(1) AA
MA-000/MH-
000
(1) 2A
PA-000/PH-000
(1) 21
HA-000
(4) NONE
OR-000
(4) 59
CR-000
(1) NONE
BV-000
(1) NONE
DF-ZZZ/DR-ZZZ
(1) NONE
DN-ZZZ/DH-ZZZ
(1) 45
TA-000/TR-000
(4) 21
JA-000
(1) 1A-17
FA-999/FH-999
(1) 1A-17
SA-998/SH-998
(3) 73
FT-999/FJ-999
(3) 73
ST-998/SJ-998
(6) A4
FI-000
(6) XX
FK-000
(5) 71
FB-ZZZ/FU-ZZZ
(4) A2
CL-UUU

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents