Event Labeling - Delphi Display Systems RDS-INSFTTCU Configuration And User's Manual

Table of Contents

Advertisement

Delphi Display Systems, Inc. RDS-INSFTTCU
The caution box surrounding the check box for Event Labeling is a warning to the user that the
®
Timer's data can be distorted when the new configuration of selected box is checked
Fast Track
is uploaded to the Fast Track
information is during the hours that the drive-thru window is closed. For more information and

4.7.5 Event Labeling

This will allow you to label (up to 8 alpha-numeric characters) your
single station and multi-station events. You can also list the order in
which the events are displayed on the Fast Track
The Name column allows you to customize the way you want your L1 –
L8 single station and/or the M1 – M4 multi station events to appear on
®
Timer's display. For example instead of L4 event
your Fast Track
saying PICK UP you may want to change it to say something else. You
are allowed up to 8 alphanumeric characters including spaces for this
field. However, GREET must always be GREET but you may add 3
more alphanumeric characters after it if you desire.
The List column allows you to list which order you want your L1 – L8
single station and/or the M1 – M4 multi station events to appear on
®
Timer's display. The order can be arranged in any
your Fast Track
fashion but must consecutively begin with the number 1 with no
duplicate number or missing numbers. An 'X' is used when the event is
not to be displayed. Caution: if the entry is wrong for the event, the
®
Timer will give an error: "L COLUMN NUMBER ERR
Fast Track
NON-CONSECUTIVE". This error must be corrected for proper Fast
®
Track
Timer operation.
The Side column allows you to choose which side the event is for in a two-lane drive-thru. Only one of
two entries is allowed for each event 'A' or 'B'. Caution: if no entry is made for the event, the Fast Track
Timer will give an error: "L COLUMN NUMBER ERR NON-CONSECUTIVE". This error must be corrected
®
for proper Fast Track
Timer operation.
The Delay column allows you to set up a delay before the event is activated. This is useful for detection
points that are frequented with traffic not necessarily with the drive-thru. The format is: 0-99 the time in
seconds, or; 2: - 9: the time in minutes. Minutes and seconds cannot be combined.
The Print column allows you to print the event each time it is completed. This option is not used in the
®
Fast Track
3000 Series Timer. Since the Timer has no printing capabilities, none of the selections
should be checked!
The ALT/MAIN Config button toggles between the MAIN CONFIGURATION and ALT CONFIGURATION
Event Labeling settings.
Do not copy or distribute without written permission from Delphi Display Systems, Inc.
~~ WARNING ~~
®
Timer during operational hours. The best time to upload this
guidance please contact Delphi Display Systems.
®