Administrator's Guide for ViewStation EX, ViewStation FX, and VS4000
Configuring the Serial V.35/RS-449/RS-530 Network Interface
3-18
To use the serial network interface for the system, you may need to configure the
following:
!
Video network settings
!
Network control signals
!
Calling profile
!
Broadcast Mode
!
Dialing speeds
!
Crypto Resync
To configure serial video network settings:
1.
Go to System Info > Admin Setup > Video Network > Video Network.
2.
Configure these settings:
Setting
RS-366 Dialing
V.35 Ports Used
Dialing Protocol
Broadcast Mode
Description
Allows users to dial calls from this system.
Uncheck this box if this is a dedicated connection or if
another device is used for dialing calls.
Specifies whether one or two lines are connected.
Specifies the protocol used by this system.
Enables support for H.331 broadcast transmissions from
this system.
This enables the system to send video and audio to many
other system, such as large satellite networks.