[2] Network > [1] Ethernet > (choose the bus module or on-board) > [1]
Module Parameters menu
You can use DCHP/AutoIP or UPnP for Ethernet communication with the on-board Ethernet or
a B426. In this menu, you can enable and disable these protocols.
DHCP/AutoIP Enable
UPnP Enable
IPv4 Address
IPv4 Subnet Mask
Default Gateway
HTTP Port Number
IPv4 Server Address
IPv6 Server Address
Module Hostname
DHCP/AutoIP Enable
B91x/B92x keypads configuration of DHCP/AutoIP Enable
1.
2.
3.
4.
5.
6.
B93x/B94x keypads configuration of DHCP/AutoIP Enable
1.
2.
3.
4.
5.
UPnP Enable
Bosch Security Systems, Inc.
Go to [1] Program > [1] Reporting > [4] Personal Note. The keypad shows the phone
number or email address of the selected destination.
Use
/[PREV] or
/[NEXT] to scroll though the list of destinations and go to the
destination you want to program.
Press [Edit] to edit the phone number or email address.
Delete existing characters, if necessary, and then enter the new characters.
Press [Save] to save the phone number or email address.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
Press [ENTER] to edit the DHCP/AutoIP Enable configuration for the module.
Use [PREV] or [NEXT] to toggle between Yes and No.
Press [ENTER] while viewing the desired option to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
Press [Yes] or [No] – whichever is available – to change the programming.
Press [Save] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Installation and System Reference Guide
Default
Module settings
Yes
Yes/No
Yes
Yes/No
0.0.0.0
_______________________________
255.255.255.255
_______________________________
0.0.0.0
_______________________________
80
_______________________________
0.0.0.0
_______________________________
0.0.0.0
_______________________________
Blank
_______________________________
Keypad Installer menu | en
2015.07 | 12 | F.01U.287.180
113