Invisible Walk Test - Bosch B5512 Reference Manual

Hide thumbs Also See for B5512:
Table of Contents

Advertisement

76
en | Program and test the control panel
15.2.4

Invisible walk test

An invisible walk test allows you to test both controlled points and 24-hr points. Points
assigned to Point Indexes with the Invisible Point parameter set to Yes.
An invisible walk test includes points meeting the following criteria:
Performing an invisible walk test:
1.
2.
3.
4.
2015.07 | 12 | F.01U.287.180
Have a point source other than Unassigned
Have a point index not set to Disabled (must be non-zero)
Have a point index configured with the point type of 24-Hour, Part On, Interior, or Interior
Follower
Are not service bypassed
Choose a keypad to conduct the test. Ensure that all areas are off (disarmed).
Enter your passcode and press [ENTER]. The keypad shows the number of points that
remain to be tested.
To view the list of points, press [ENTER] or [View untested points]. To scroll through the
list of points, use
/[PREV] or
When your fault a point (open a door for example), the keypad emits a brief tone and
shows the name.
Installation and System Reference Guide
/[NEXT].
Control Panel
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B3512B5512eB4512eB3512eB4512

Table of Contents