5.2.6.5
Example, aluminium welding (latched special)
I
P
Basic parameters
Welding parameter
GASstr
GASend:
RUECK
"P
" start program
START
DVstart
ustart
tstart
"P
" main program
A
"P
" reduced main program
B
DV3
U3
"P
" end-crater program
END
tSend
DVend
Uend
tend
Item No.: 099-005073-EWM01
START
P
A
Meaning / explanation
Gas pre-flow time
Gas post-flow time
Wire burn-back length
Wire speed
Arc length correction
Duration
Setting the wire speed
Wire speed
Arc length correction
Slope duration from P
Wire speed
Arc length correction
Duration
Functional characteristics
P
B
Figure 5-21
or P
to P
A
B
END
MIG/MAG welding
P
END
t
Setting range
0.0s to 20.0s
0.0s to 20.0s
2 to 500
0% to 200%
-9.9V to +9.9V
0.0s to 20s
0% to 200%
-9.9V to +9.9V
0.0s to 20s
0% to 200%
-9.9V to +9.9V
0.0s to 20s
43