5.2.11 Special parameter, "M3.70/M3.71"

The special parameters cannot be viewed directly since they are normally only set and stored once. The
machine control offers the following special functions:

5.2.11.1 Special parameters list

Function
P1
Ramp time for wire inching
P2
Block program "0"
P3
PowerControl torch display mode
P4
Program limitation
P5
Special cycle in the special latched
and non-latched operating modes
1
P6
Enable special jobs SP1 to SP3
P7
Correction operation, threshold value
setting
2
P8
Program changeover with standard
torch
P9
Lat. and sp. lat. tapping start
2
P10
One or two-wire feed operation
P11 Special latched tapping time
2
P12
JOB list changeover
2
P13
Lower limit
remote JOB changeover
2
P14
Upper limit
remote JOB changeover
P15 Hold function
3
Key
Software key switch
1) PHOENIX EXPERT range only
2) PHOENIX EXPERT und PROGRESS ranges only
3) PHOENIX BASIC range only
4) See note in the relevant section of this chapter
Item No.: 099-005073-EWM01
Functional characteristics
Setting options
0 = normal inching (10s ramp time)
1 = fast inching (3s ramp time)
0 = P0 enabled
1 = P0 blocked
0 = normal display
1 = alternating display
Programs 2 to max. 15
0 = normal (previous) non-latched/latched
1 = WF3 cycle for non-latched/latched
0 = no enabling
1 = enabling of Sp1-3
0 = correction operation switched off
1 = correction operation on
"Main program (PA)" flashing
0 = no program changeover
1 = special latched
2 = specific latched special (n cycle active)
0 = no latched tapping start
1 = latched tapping start possible
0 = single operation
1 = dual operation, this unit is the "master"
2 = dual operation, this unit is the "slave"
0 = tapping function switched off
1 = 300ms
2 = 600ms
0 = task-oriented JOB list
1 = actual JOB list
2 = actual JOB list, JOB changeover activated
via accessories
Lowest JOB that can be selected using
PowerControl 2 torches.
Highest JOB that can be selected using
PowerControl 2 torches.
0 = hold values are not displayed
1 = hold values are displayed.
0 = system complete
1 = system not complete
MIG/MAG welding
Ex
works
1
0
0
15
0
0
0
0
0
0
1
4
0/1
129
169
1
1
49

Hide quick links: