4.2
Cleaning the spraygun and replace the wear parts
3
2
1
Never place the spraygun or parts of it into any wet cleaning agent!
Caution
•
Clean the dismantled parts and the spraygun of powder deposits.
•
Normally it is only necessary to check the protective wedge 4 for wear, and to replace it
with a new one if necessary.
•
Check before re-assembling whether the contact points on the nozzle insert 3 and the
inside of the gun housing 5 have been thoroughly cleaned, so that the tip of the electrode
makes a conducting connection to the high voltage generator.
•
Carefully re-fit the nozzle insert in the gun housing and tighten it up with the outer nut.
•
Slide the deflector cone onto the nozzle insert again.
•
The spraygun is again ready for operation.
02/01
PEM-C2
5
4
•
Pull off deflector cone 1 from nozzle insert 3.
•
Unscrew the outer nut 2 from the gun housing 5.
•
Carefully draw the nozzle insert 3 out of the gun
housing 5.
•
Separate the protective wedge 4 from the
nozzle insert 3.
16