Recommended powder output volumes depending on the
powder hose
inner diameter
[mm]
10
11
12
3.2

How to switch off the spraygun

The spraygun is switched off in different ways, depending on the type of powder injector.
The spraygun should be blown through (flushed) and cleaned from powder
deposits with every interruption of work. In this way powder deposits and
Hint
surges on switching on again are to a great extent avoided.
The flushing procedure can be set on the control unit if the spraygun is connected to an EPG
Digiflow in conjunction with the PJ-D1 powder injector. In this case the spraygun is blown free
of powder as soon as the trigger is released.
If the spraygun is operated with an EPG 2007 control unit and a PJ 2020 PRS powder
injector, proceed as follows:
Release the trigger on the spraygun so that the powder supply and high voltage generator
are switched off.
If you do not wish to alter the settings for the feeding air and dosage air, in order to carry
on coating with the same powder cloud, pull out the powder injector from the powder
container's injector connection. No more powder will be delivered when switching on
again.
Press the trigger on the spraygun so that the spraygun is blown free of powder.
Switch the control unit off and secure it against being switched on unintentionally.
02/01
PEM-C2
internal diameter of the hose
feeding air + dosage air
3
[Nm
/ h]
ca. 2.8 ... 4.8 ( 98.8 ... 169.4 ft
ca. 3.3 ... 5.8 (116.5 ... 204.7 ft
ca. 3.7 ... 6.8 (130.6 ... 240.0 ft
13
powder output
(standard values)
[g / min]
3
/h)
3
/h)
50 ... 250
3
/h)
100 ... 350
... 100