8.

Specification

Weight:
Electrical:
input voltage:
input current:
frequency:
output voltage:
output current:
polarity:
design:
protection class:
Pneumatic:
input air pressure (atomizing air):
powder output volume:
Compressed air quality according to ISO 8573.1:
residual water content in compressed air: max. 1.3 g H
residual oil content in compressed air:
residual dust content in compressed air:
Volume measures:
All volume indications (m
Hint
meter of a gas at 0 °C and 1.013 bar is called norm cubic meter.
1 Nm
Ambient conditions:
If low temperature powders are used, the ambient temperature may have to be lower than
30 °C.
02/01
3
/h) are Nm
3
3
/h = 35.3 ft
/h
PEM-C2
498 g
max. 22 Vpp
max. 0.9 A
19 ... 30 kHz
max. 100 kV DC
max. 160 µA DC
negative
according to EN 50050
IP 54
max. 3 bar
max. 450 g/min
max. 0.01 mg oil/Nm
max. 1 mg dust/Nm
3
/h. (norm cubic meters per hour). One cubic
21
3
O/Nm
at a dew point of 7 °C
2
3
3
0351801