Replacing The Power Cable; Typical Wear Parts - WAGNER SF23 PRO Operating Manual

Airless high-pressure spraying unit
Hide thumbs Also See for SF23 PRO:
Table of Contents

Advertisement

GB
REPAIRS AT THE UNIT
10.4

REPLACING THE POWER CABLE

This may only be carried out by a skilled elec-
trician. No liability is assumed for incorrect
installation.
Switch the unit off.
Before all repair work: Unplug the power
plug from the outlet.
1. Remove the cover (1) by loosening the screws.
2. Loosen the cable threaded joint (2).
3. Loosen the wires (3).
4. Replace the unit connecting line.
(only an approved power cable with the designation H07-
RNF with a splash-proof plug may be used).
5. Connect the green/yellow wire to the contact with the PE
sign.
6. Remount the covers carefully (do not squeeze any cables!)
10.5

TYPICAL WEAR PARTS

Despite the use of high-quality materials the highly abrasive
effect of the paints means that wear can occur at the follow-
ing parts:
Inlet valve
For replacing refer to Section 10.1
(failure becomes noticeable through performance loss and/or
poor or no suction)
Outlet valve
For replacing refer to Section 10.2
(failure becomes noticeable through performance loss and/
or poor suction) The outlet valve is usually considerably more
durable than the inlet valve. Thorough cleaning may already
help here.