Clear Memory - CAS LP-II Service Manual

Hide thumbs Also See for LP-II:
Table of Contents

Advertisement

8 System Options
The second screen looks like this:
lb/kg key: If you set this to Y then
the lb/kg key will work in sales
mode and allow you to switch
between lb & kg modes. If you
set this to N then you will not be
allowed to switch between lb &
kg modes.
Remember the scale will only work in the calibrated unit when this option is N. Also, PLUs programmed
for a unit other than the calibrated unit will not be accessible when this option is N. This means that if
this option is set to N and the scale was calibrated in kg, then only kg PLUs will work and the scale will
only weigh in kg.
1/2, 1/4, & 100g keys: If this is set to Y then these keys will in sales mode (1/2 & 1/4 in lb mode.) If this
option is set to N, then these keys will not work in any mode. Remember, some states require that these
keys be disabled.
ADD key: The ADD key is used to combine multiple sales onto 1 label while still issuing individual labels.
If this is set to Y then the ADD key will be operational. If this option is set to N, then the ADD key will not
be operational.
TARE key: The TARE key is used to enter tares manually (using 0 ~ 9 keys to enter tare weight) and platter
tare (placing empty container on the platter). If this is set to Y then the TARE key will be operational. If
this option is set to N, then the TARE key will not be operational & only PLU programmed tares will be
allowed.
Numeric Tare: If this is set to Y then the TARE key will allow manual tares. If this option is set to N, then
the TARE key will not allow manual tares (using 0 ~ 9 keys to enter tare weight.)
00 key: If this is set to Y then the 00 key will work the same as pressing the 0 key twice. If this option is set
to N, then the 00 key will not work at all (do nothing.)
Misc PLU keys: If this is set to Y then the 3 Misc PLU keys will work. If this option is set to N, then the 3 Misc
PLU keys will not work as Misc PLU keys; instead they will operate as Speed Keys 54, 55, & 56 (unshifted) &
110, 111, & 112 (shifted) respectively.
PLU Unit Conversion: If this is set to Y then PLUs programmed will be switched from pound to metric
weighing.

8.4 Clear Memory

Once at the CAL Main menu screen,
press the 2 key. The System Options
Menu screen will appear as follows. At
the System Options Menu screen, press
the 4 key for Clear Memory.
(2/2)
< CAL: KEYPAD OPTIONS >
Numeric Tare Allowed
Double Zero Key Allowed
Misc PLU Keys Allowed
PLU Unit Conversion Allowed
< CAL: SYSTEM OPTIONS >
1. WEIGHT OPTIONS
2. NON-WEIGHT OPTIONS
3. KEYPAD OPTIONS
4. CLEAR MEMORY
5. SELECT COUNTRY
31
INS/CAPS
? (Y/N) :[Y]
? (Y/N) :[Y]
? (Y/N) :[Y]
? (Y/N) :[Y]
< CAL: CLEAR MEMORY >
1. NON-VOLATILE MEMORY
2. STATIC RAM
3. EEPROM
4. ALL MEMORY

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents