Summary of Contents for CAS CI-200 Series

  • Page 2 Cautions for Your Safety...
  • Page 3 Warning...
  • Page 4 Attention...
  • Page 5: Table Of Contents

    Contents 1. Features 2. Specifications in Appearance 3. How to Install 4. Weight Setup Mode 5. Set Mode 6. Test Mode...
  • Page 6 7. System Mode 8. General Function Descriptions 9. Weighing Mode 10. Charge and Use Time 11. RS-232C Interface in Detail 12. Error Message...
  • Page 7 Preface...
  • Page 8: Features

    1. Features 1-1. Features 1-2. Major Functions...
  • Page 9 1-3. Analog and A/D Conversion Applied voltage for load cell Zeroing range Input sensitivity Non-straightness A/D internal resolution A/D external resolution A/D conversion speed Weight setup 1-4. Digital and Display Weight display Character size Sign below zero point Sign for status...
  • Page 10 1-5. General Specifications AC Adapter Operating temperature CI-200A CI-201A Product size CI-200S CI-200SC CI-200A CI-201A Product weight CI-200S CI-200SC 1-6. Communication and Option Basic Optional...
  • Page 11: Specifications In Appearance

    2. Specifications in Appearance 2-1. External Dimension (CI-200A, CI-201A)
  • Page 12 (CI-200S, CI-200SC)
  • Page 13 2-2. Front Panel Descriptions...
  • Page 14 (1) Main Display (Weight Display) (2) Status Display (Lamp) LED Lamp LCD Status Display Descriptions Stable Net weight Zero point Hold High limit Low limit Normal Tare Communicat Summatio n lamp Quantity lamp Percent lamp...
  • Page 16 (1) Main Display (Weight Display) (2) Status Display (Lamp) Stable Tare Net weight Hold Zero point Communication Lack Fixed Quantity Excess...
  • Page 17 (3) Keyboard...
  • Page 19 SEALING (CAL S/W) POWER LOAD CELL RS-232C...
  • Page 20 SEALING, F/G RS-232C LOADCELL POWER SEALING (CAL S/W) POWER LOAD CELL RS-232C...
  • Page 21: How To Install

    3. How to Install 3-1. How to Connect Load Cell Number...
  • Page 22: Weight Setup Mode

    4. Weight Setup (Calibration) Mode 4-1. Weight Setup Menu (CAL1 – CAL9)
  • Page 23 CAL 1 (CAL 1 automatically starts.) Function: Setting Maximum Value Range of set value: 1 ~ 99,999 CAL 2 Function: Minimum division and decimal position setting Range of set value: 0.001 ~ 9999...
  • Page 24 3 CAL CAL 3-1 Function: Setting Multi Calibration Step Range of set value: 1 ~ 5 mV/V (full span) Multi-point Multi-point Real curve Ideal Multi-point Multi-point Multi-point weight (zero span) Z ero and Sp an points to interpolate weight from Load Cell...
  • Page 25 CAL 3-2 Function: Zero Calibration CAL 3-3 Function: Setting Weight Range of set value: 1 ~ 99,999...
  • Page 26 CAL 3-4 Function: Weight Calibration) CAL 7 Function: Gravity Adjustment...
  • Page 27 CAL 8 Function: Zero adjustment - calibration when any zeroing error occurs. CAL 9 Function: Factor Calibration...
  • Page 28 CAL 10 CAL 10-1 Function: Setting Dual Range Range of set value: 0 ~ 1 CAL 10-2 Function: Setting the applied section for the Dual Range Range of set value: 0 ~ 99999...
  • Page 29 4-2. How to Seal the Indicator (Sealing) Sealing Point...
  • Page 30: Set Mode

    5. Set Mode 5-1. How to Enter the Set Mode 5-2. Descriptions on key operations in the Set Mode...
  • Page 31 5-3. Set Menu Descriptions (F00 ~ F99) General Function...
  • Page 32 RS-232 Serial Communication Function Print Function...
  • Page 33 Checker Function Set Mode Initialization...
  • Page 34 5-3-1. General Function Function Date Change Function Time Change Function Auto Power OFF F03. 00 Function Setting A/D Converting Speed F04. 10 Function Setting digital filter F05. 10...
  • Page 35 Function Setting vibration filter F06. 00 Function Setting Motion Detection Condition F07. 2 Function Setting Automatic Zero Tracking Compensation F08. 2...
  • Page 36 Function Weight Backup Function F09. 0 Function Set Hold Type F10. 0 Function Set average hold time Function Auto Hold Range Function Set Zero Range F13. 10 Function ZERO and TARE Keys Availability F14. 1...
  • Page 37 Function Set the front key input to be allowed. F16. 0 Function Set the use of function key 1 Function Set the use of function key 2 Function Set the use of unit F19. 0...
  • Page 38 Function Set the initial zero range F21. 10 Function Setting the range of check for the excessive weight (weighing unit) F23 09 F24(CI-201A) Function Backlight Operation F24 0...
  • Page 39 Function Set Backlight and LED Brightness F25 3...
  • Page 40 5-3-2. RS-232 (Serial Communication) Function Function Set Device ID F26. 00 Function Set Parity Bit – RS232C & PRT F27. 0...
  • Page 41 Function Set COM1 Baud Rate F28. 4 Function Set COM1 - Usage F29 0 Function Set COM1 - Output Format Function Set COM1 - Output Mode F31 0...
  • Page 42 Note 1. Command Mode Table Descriptions on CI-200 Data Request Signal of CI-200 Request Signal Output Signal...
  • Page 43 Note 1. NT-200 Command Mode Table Read Write Format for Device ID Change...
  • Page 44 Function Set COM2 Baud Rate F32 4 Function Set COM2 - Usage F33 1 Function Set COM2 - Output Format F34 0 Function Set COM2 - Output Mode F35 0...
  • Page 45 Function Set a printer to use F40 2 Function Set print format F41 0 Function Set automatic print F42 0 Function Set Line Feed F43 1...
  • Page 46 Print Format 0 Print Format 1 Print Format 2...
  • Page 47 Total Print Format Total Format - -- - -- - -- -- - -- - -- - -- - -- -- - -- - -- - -- -- - -- - - ID_01 TOTAL - -- - -- - -- -- - -- - -- - -- - -- -- - -- - -- - -- -- - -- - - 2004.06.24 14:32:54 COUNT...
  • Page 48 Variable Descriptions Command (ASCII code) Descriptions Status Function Enter the user output message...
  • Page 49 Function Set print output F45 1 Function Initialize data after the summation is printed. F45 1 Function Setting print item number F45 1...
  • Page 50 5-3-4. Checker Function Function Select the weighing mode (LCD, SC Only) F50 0 [CHECKER MODE] Weight (Low Limit) (High Limit) Comm 0 kg 50 kg 100 kg Signal HIGH [LIMIT MODE] Weight (Low Limit) (High Limit) Comm 0 kg 50 kg 100 kg Signal HIGH...
  • Page 51 Function Set Buzzer On/Off on the Checker Function (LCD, SC Only) F51 0 Function Password Change Function Set default...
  • Page 52: Test Mode

    6. Test Mode 6-1. How to Enter the Test Mode 6-2. Test Menu (TEST 1 - TEST10)
  • Page 53 Function: Key test Used key Display Descriptions Number Code Number Code Number Code Function: Display Screen Test Used key Display Descriptions...
  • Page 54 Function: Load cell test and A/D conversion test Used key Display Descriptions Function: Serial Communication Test Used key Display Descriptions...
  • Page 55 Function: Printer Test Used key Display Descriptions Function: EEPROM Test Used key Display Descriptions...
  • Page 56 Function: Battery test Used key Display Descriptions Function: RTC Test Used key Display Descriptions...
  • Page 57 7. System Mode 7-1. How to Enter the System Mode Load Descriptio Step Display Screen and Key Input Tray...
  • Page 58 Weighing Mode (I) Initial Screen Descriptions Counting Mode (II) Initial Screen Descriptions Percent Mode (III) Initial Screen Descriptions...
  • Page 59 7-2. PCS MODE 7-2-1. PCS MODE Sample Input Method Load Step Display Screen and Key Input Descriptions Tray...
  • Page 60 7-2-2. PCS Mode Direct Input Method Load Step Display Screen and Key Input Descriptions Tray...
  • Page 61 7-3. PERCENT MODE 7-3-1. Percent Mode Sample Input Method Load Step Display Screen and Key Input Descriptions Tray...
  • Page 62 7-3-2. Percent Mode Direct Input Method Load Step Display Screen and Key Input Descriptions Tray...
  • Page 63 8. General Function Descriptions 8-1. Item Number (Unique Number of Weighing Item: ID) Input Method Load Step Display Screen and Key Input Descriptions Tray 8-2. Key Tare Input Method Load Step Display Screen and Key Input Descriptions Tray...
  • Page 64 8-3. How to Check Subtotal, Total and Weighing Count Descriptions Subtotal is erased after it is printed. Total is erased after it is printed.
  • Page 65 8-4. How to Enter High Limit Load Step Display Screen and Key Input Descriptions Tray 8-5. How to Enter Low Limit Load Step Display Screen and Key Input Descriptions Tray...
  • Page 66 9. Weighing Mode 9-1. Zeroing Function (used when the zero point changes) - LED Range of zero point: within a range set in F13 9-2. Tare Function (used for weighing with a container) - LED Maximum tare set range: maximum weight If you want to know the total weight;...
  • Page 67 9-3. Hold Function (used for weighing moving objects) - LED Ordinary Hold Function (hold function is performed when the hold key is pressed.) Automatic hold function (the hold function is performed by automatically calculating the maximum weight of moving objects.) It returns to the normal status and the hold lamp is turned off if you empty the load tray or press the hold key to release the held weight value.
  • Page 68 9-4. Zeroing Function (used when the zero point changes) - LCD Range of zero point: within a range set in F13 9-5. Tare Function (used for weighing with a container) - LCD Maximum tare set range: maximum weight If you want to know the total weight; If you want to know the net weight;...
  • Page 69 9-6. Hold Function (used for weighing moving objects) - LCD Ordinary Hold Function (hold function is performed when the hold key is pressed.) Automatic hold function (the hold function is performed by automatically calculating the maximum weight of moving objects.) It returns to the normal status and the hold lamp is turned off if you empty the load tray or press the hold key to release the held weight value.
  • Page 70 10. Charge and Use Time 10-1. How to Use and Charge the Chargeable Battery 10-2. Use Time of the Battery Condition Use Time...
  • Page 71 11. RS-232C Interface in Detail 1. RS-232C Port Connection O 2 Transmit Data O 3 Receive Data O 7 Signal Ground O 8 Carrier Detect O 20 Data Terminal Ready O 6 Data Set Ready O 4 Request to Send O 5 Clear to Send O 2 Transmit Data O 3 Receive Data...
  • Page 72 11-2-1. How to Connect an Auxiliary Display O 3 Receive Data O 7 Signal Ground 11-2-2. How to Connect a Label Printer (DLP) O 3 Transmit Data O 2 Receive Data O 5 Signal Ground 3. RS-232 Communication Protocol 11-3-1. 22 Bytes for CAS...
  • Page 73 11-3-2. 10 Bytes for CAS 11-3-3. 18 Bytes for AND...
  • Page 74 RS-422 & 485 Serial Communications (COM2) Setting output method Signal Format and Data Format...
  • Page 75 12. Error Message 12-1. Error Message from the Weight Setup Mode Error Cause Solution...
  • Page 76 12-2. Error Message from the Weighing Mode Error Cause Solution Err 01 Err 02 Err 05 Err 08 Err 09 Err 10 Err 12 Err 13 Err 15 Err 82 Over...