Table 10. Alert Codes and Troubleshooting
Alert
PRIORITY
Code
CONDITION
124
Critical
125
Critical
126
Critical
130
Moderate
131
Critical
face or IHarmony
Air handler, equip
132
Critical
507343-01
APPLICABLE
SYSTEM
COMPONENTS
Thermostat, fur
nace, air handler,
The thermostat has lost com
outdoor unit,
munication with a system com
equipment inter
ponent for more than three min
face or IHarmony
utes.
damper control
module
Thermostat, fur
nace, air handler,
outdoor unit,
There is a hardware problem
on a system component con
equipment inter
trol.
face or IHarmony
damper control
module
Furnace air han
There is an internal communi
cation problem with a system
dler or outdoor
component.
unit
Equipment inter
Air handler jumper is missing.
face module
Thermostat, fur
nace, air handler,
outdoor unit,
System component control pa
equipment inter
rameters are corrupted.
damper control
module
ment interface
System component control
module or IHar
software is corrupted.
mony damper
control module
Critical alerts are displayed on the Home screen, in the Home
owner alert button, and in the Installer alert button. Minor and
moderate alerts are found only in the Installer alert button.
COMPONENT OR SYSTEM OPERA
ALERT TEXT
Page 48
TIONAL STATE AND TROU
BLESHOOTING TIP
System component has lost com
munication with the thermostat.
Check the wiring connections.
Ohm wires.
Cycle power.
This alert code stops all associat
ed system operations and waits
for a heartbeat message from the
system component that is not
communicating.
There is a control hardware prob
lem.
Replace the control if the problem
prevents operation and is persis
tent.
Damper control module will re
main in non-zone mode (all
dampers open) for five minutes
after priority condition no longer
exist.
There is an internal hardware
problem on the system compo
nent control.
Typically the system component
control will reset itself.
Replace the system component
(device) control if the problem
prevents operation and is persis
tent.
Configuration jumper missing on
equipment interface module.
NOTE: This is applicable in non-
communicating applications only).
Install the missing jumper.
Reconfigure the system.
Replace the system component
control if heating or cooling is not
available.
Recycle power.
If failure re-occurs, replace the
system component control.
HOW TO CLEAR
ALERT CODE
Automatically clears
after communication is
re-established with ap
plicable system com
ponent (device).
Automatically clears
300 seconds after the
issue no longer exists.
Automatically clears
300 seconds after the
issue no longer exists.
Automatically clears
after the missing or in
correctly installed
jumper is installed or
corrected.
Will automatically clear
when system compo
nent (device) passes
memory self-test or
system component
control is replaced.
Manual system power
reset is required to re
cover from this alert
code.