System Devices Screen — Humiditrol Comfort Adjustment - Lennox iComfort Wi-Fi Setup Manual

Touch screen programmable communicating thermostat
Hide thumbs Also See for iComfort Wi-Fi:
Table of Contents

Advertisement

®
Partial iComfort
System — Adjusting Dehumidification Settings (Non-Communicating
Outdoor Unit)
SYSTEM DEVICES SCREEN — HUMIDITROL COMFORT ADJUSTMENT
Pre-adjustment REQUIREMENTS:
1st, the device has been installed
2nd, from the Add or Remove Non-communicating equip­
ment?, press next.:
3rd, in the Adjust a setting... screen, configure the device
as follows
system devices
System
Air Conditioner
Furnace
Thermostat
Humiditrol
System
3rd Stage Delay
4th Stage Delay
Lock In 2nd Stage HP by Outdoor Temp
Balance Point Control
Humiditrol Comfort Adjust
Min De-humidification Setpoint
Humiditrol Comfort Adjust
Select one
Maximum Overcooling
Minimum Overcooling
3a
save
Humiditrol Comfort Adjust set­
tings are only available on units
equipped with a Humiditrol
De-humidification device.
Figure 16. Adjust a Non-Communicating Device Setting — Dehumidification
FEATURE SCREEN — DEHUMIDIFICATION SETTINGS
1. From the main screen, press the right arrow icon to go
the the Features screen.
2. From the Features screen, select system settings.
3. Touch the button of the dehumidification settings you
want to adjust; if it says dehumidifier OFF, one touch will
display a selection for OFF, MEDIUM or HIGH.
4. Selecting MEDIUM or HIGH will bring on the set-to but­
ton.
5. When you touch the set-to button, the arrows appear, al­
lowing you to change to the desired dehumidifier per­
centage setting
507343-01
To adjust a setting,
highlight it,
then press Edit
System
1a
1b
De-humidification Control Mode
current value:
Midpoint Overcooling
2a
2b
Midpoint Overcooling
back
System
Staged Delay TImers
cancel
2nd Stage Delay
3b
3rd Stage Delay
4th Stage Delay
Lock In 2nd Stage HP by Outdoor Temp
Balance Point Control
®
Humiditrol Comfort Adjust
Min De-humidification Setpoint
OD/Humid Boundary
Outdoor Temperature Reading Calibr
9:39 am Aug 15, 2012
Figure 17. Dehumidification Settings Controls
1. In the "system devices" list, use the arrows (1a) to
highlight System. Press edit (1b).
2. Humiditrol
rows (2a) to highlight Humiditrol Comfort Adjust.
The current value defaults to Maximum Overcooling.
Press edit (2b).
3. Humiditrol
(3a) to select the overcooling level; press save (3b).
about
(After saving, check that the current value now
shows the new selection).
resetAll
4. Use arrows (4a) to highlight Min De-humidification
edit
Setpoint; press edit (4b). Note the current value
(e.g. 45).
reinstall
5. Use arrows (5a) to make changes; press save (5b).
(After saving, check that the current value now
reset
shows the new selection).
6. Press the back button to return to "Adjust a set­
edit
ting..." screen.
De-humidification Control Mode
current value:
45
4a
6
back
SYSTEM SETTINGS
humidifier
is ON
ALL CHANGES MADE ON
THIS SCREEN ARE IN­
STANTLY SAVED.
Wi-Fi
9:39 am Aug 15, 2012
Page 20
®
only—In the "System" list, use the ar­
®
only — Press one of the radio buttons
Min De-humidification
Setpoint
4b
Range is 40 to 60
Default is 45, inc:1
edit
set-to
42 %
reset
5b
save
(returns to
adjust a
setting
screen)
humidification
De-humidification
settings
settings
OFF
%
de-
40
humidifier
MEDIUM
MEDIUM
set to
HIGH
current indoor humidity is 50%
5a
cancel
humidifier
%
50
display
is ON
set to
(default is ON)
?

Hide quick links:

Advertisement

Table of Contents
loading