3.4
[Page 3] 5. SMALL BUOY DETECTION
• In this mode, the signal processing circuit loss is low when small buoy are detected.
OFF
: Normal signal processing setting.
ON
: The radar interference processing circuit is switched to small buoy detection
processing.
[Page 3] 6. AUTOMATIC DR CONTROL (AUTO DR CONT)
• Automatically controls "VIDEO LATITUDE" (dynamic range) when automatic STC or FTC is used.
• At automatic STC, this mode expands the dynamic range only for the area with strong sea clutter and
reduces the dynamic range for the area without sea clutter, enhancing the sensitivity.
• At automatic FTC, the mode expands the dynamic range of the area with strong sea clutter and rain/
snow clutter and reduces the dynamic range of other areas, enhancing the sensitivity.
• When automatic FTC is used, land images become weak.
OFF
: DR (dynamic range) automatic control is not performed.
The dynamic range (video latitude) is the same setting as that of manual STC.
ON
: Performs automatic DR control. (normal setting)
Page 3
1. VIDEO LATITUDE
2. VIDEO NOISE REJECTION
3. GAIN OFFSET
4. XMIT REPETITION FREQUENCY
5. SMALL BUOY DETECTION
6
AUTO DR CONT
Low loss IR processing ➝ IR1 of small buoy detection
Normal IR1 ➝ IR2 of small buoy detection
Normal IR2 ➝ IR3 of small buoy detection
However, the interference elimination performance of low loss IR processing
is lower than that of normal IR processing.
NORMAL
WIDE
OFF
LEVEL1
± NUMERIC VALUE
NORMAL
HIPOWER
OFF
ON
OFF
ON
3 – 71
NARROW
LEVEL2
ECONOMY