CDM-740 Advanced Satellite Modem
Front Panel Operation
5.4.4

CONFIG: Remote

Remote Control= Local
Select Local, Serial, or Ethernet using the ◄ ► arrow keys, then press ENTER.
If Local is selected, then reconfiguration via Serial Remote or Ethernet is not permitted.
Remote monitoring is still possible.
5.4.4.1
(CONFIG:) Remote
Serial 485 Address: 0001
Baud Rate: 38400(Read only)
To edit the Serial 485 Address, select each digit of the Address using the ◄ ► arrow keys, then edit
the valuve of that digit using the
range is 0001 to 9999.
Note: Address 0 is reserved for universal addressing. Character format is not selectable and is fixed
at 8-N-1.
5.4.5
CONFIG: IP
IP Config: GE1
SNMP: Read-Cmty Write-Cmty Trap
On the top line, select GE1, GE2, or Mgmt using the ◄ ► arrow keys, then press ENTER to edit
the pertinent IP Configuration parameters. Note that, with the exception of the screen label, the
function of these three IP configuration submenus is identical. For brevity, all three are explained
next in Sect. 5.4.5.1.
On the bottom line, using the ◄ ► arrow keys to select the SNMP Configuration parameter to edit
(Read-Cmty, Write-Cmty, or Trap). Refer to Sect. 5.4.5.2 through Sect. 5.4.5.4 for further
details.
Serial
Serial
arrow keys. Press ENTER when done. The permitted address
▲ ▼
GE2
Mgmt
5–15
Ethernet
◄►
(
E)
v E)
◄►
(
◄►
(
)
Revision 0