8. Removal of Touch Sensor PCB / Signal Receiver
PCB / Display PCB
Procedure
Step
1
Remove the 6 thermal
insulators.
2
Remove the 6 screws.
3
Remove the front panel
insulator.
Release the 4 screws of
4
the indication lamp
cover assembly.
Disconnect the
5
connector [S53] from
the touch sensor PCB.
Removal Procedure

Removal of Touch Sensor PCB / Signal Receiver PCB / Display PCB

Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Thermal insulator
Front panel
insulator
Indication lamp cover assembly
Touch sensor PCB
[S53]
Points
Remove the front panel
according to "Removal of
Front Panel".
Each screw has a washer.
When reassembling, make
sure to attach the washers.
(R11552)
(R11553)
[S53] : display PCB
(R11554)