MR HEAD, BRUSH UNIT
Solder bridge
White(AF-L FPC)
Green(AF-L FPC)
INSPECTION AND ADJUSTMENT FOR THE WAVEFORM OUTPUT FROM MR ENCODER
● In case of disassembling or replacing the MR head, be sure to conduct adjustment.
1.Equipment and tools to be required
・Single output rated voltage power supply: 1 unit With 5.0V and 100mA, applicable to the self-made tool
・Oscilloscope: 1 unit
・Self-made tool: 1 unit
2.Prepare the measuring lens
・Solder the lead wire on the soldering bridge that attatches the MR head and connect with each measuring instrument.
(ref. the next page)
● Solder the soldering bridges and each wire.
White(Brush unit)
Yellow(Brush unit)
- L20 ・ AF-S VR 70-200/2.8G -
JAA78151-R.3584.A
Screw Lock
# 112
B89
MR head
# 96 × 2
INC