Before entering the service
menu always cancel the
currently selected program
first, by pressing the power
button to turn the unit on then
holding down the start/stop
button for three seconds.
Main power switch
Turn off the main power switch, wait at least 5 seconds. Press and hold the Program and Start
buttons. Turn on the main power switch, wait until the LEDs have lit, release the Program and Start
buttons. The most recent fault code if there is one will be shown in display D2 AND D3.
Press the Program button to activate the component test. These are activated in order after each
button press and are shown in D3.
1. Fill valve and mixer valve
2. Fill valve only
3. Salt valve (not applicable)
4. Dispenser
5. Circulation pump
6. Circulation pump and element (max 167 F)
7. Fan and Wax motor
8. Drain pump

Service menu DW 70.5

78