Service Menu Dw 70.1 - Asko 3,000 Series Training Manual

Table of Contents

Advertisement

Before entering the service
menu always cancel the
currently selected program first,
by pressing the power button to
turn the unit on then holding
down the start/stop button for
three seconds.
Main power switch
To activate the service menu – turn off the main power switch. Wait for at least 5 seconds, keep the
program and start buttons depressed, then turn on the main switch, then release the program and start
buttons. L7 flashes. Press the program button to activate the component test. These are activated in order
after each button press: 1. Inlet valve, 2. Salt valve (not applicable), 3. Dispenser, 4.Circulation motor, 5,
Circulation motor and element (max 167 F), 6. Fan and wax motor, 7. Drain pump.
Adjust water intake (done in service menu)
Press and hold the program button for three seconds.
L1 unlit: Fill controlled by flow meter. L1 lit: Time controlled fill. Confirm selection by pressing Start. The
program returns to the main menu.