Water level 3,000 series units

If the control unit is changed from flow meter to timed fill or vise versa,
always check the water level at the lower wash tower
Always allow the machine to take in and pump
out water a few times before checking the level.
Check the level at the lower wash tower
Overflow level = 6.5 litres
Without Spray arm diverter = 3.1
litres (1.5 mm above the level)
With Spray arm diverter = 2.7 litres
(0.5 mm below the level)
17