Before entering the
service menu always
cancel the currently
selected program first,
by pressing the power
button to turn the unit on
then holding down the
start/stop button for three
seconds.
Main power switch
Turn off the main switch, wait for at least 5 seconds. Keep the program and start buttons depressed
and turn on the main switch, release the program and start buttons. The most recent fault will be
indicated as L1 – L6.
Press the program button and index through the following components: 1. Inlet valve, 2. Salt valve (not
applicable), 3. Detergent dispenser, 4. Circulation pump, 5. Heating element & circulation pump (max
167 F), 6. Fan, 7. Drain pump.