Before entering the
service menu always
cancel the currently
selected program first,
by pressing the power
button to turn the unit on
then holding down the
start/stop button for three
seconds.
Main power switch
To adjust the water intake.
Keep the program button depressed for three seconds to adjust the water intake. After week 16, 2005.
Press the program button and index through the following: L1-L6 extinguished normal volume. L1 lit:
water increased by 5%, L2 lit: water increased by 10%, L3 lit: Time controlled intake, L4 lit: Increase
time control by 5%, L5 lit: Increase time control by 10%, L6 lit: Time control increase by 15%. Confirm
choice by pressing Start button. The program returns to the main menu
Before week 16, 2005.
Press the program button and index through the following:
L1-L6 extinguished: Normal volume. L1 lit: Water reduced by 10%, L2 lit: Water reduced by 5%, L3 lit:
Time controlled intake, L4 lit: Water increased by 5%, L5 lit: Water increased by 10%, L6 lit: Water
increased by 15%. Confirm choice by pressing start button. The program returns to the main menu.