Service Menu Dw 70.3 - Asko 3,000 Series Training Manual

Table of Contents

Advertisement

Service menu DW 70.3

Before entering the service
menu always cancel the
currently selected program
first, by pressing the power
button to turn the unit on
then holding down the
start/stop button for three
seconds.
Main power switch
Turn off the main power switch. Wait at least 5 seconds. Press and hold the program and start
buttons, turn on the main switch, wait for the teardrop symbol to light on the right side of control,
release the program and start buttons. L10 AND L11 flash.
Most recent fault if there are any is indicated by L1 – L6
Before activating the component test it is necessary to manually activate the door latch so
that the door switch will be closed with the door open. Then follow the sequence below
Press program button to activate the component test. These are activated in order after each
button press.
1. Inlet valve L1 and L2 lit
2. Salt valve (not applicable).
3. Dispenser. L4 lit
4. Circulation pump. L5 lit
5. Circulation pump and element (max. 167 F) L6 lit
6. Fan and wax motor. L1 and L2 lit
7. Drain pump. L1, L2 and L3 lit