Troubleshooting The Built-in Filtration System (cont.)
Little or none, but
it is squirting out
aroung gasket.
Probable causes are power
shower holes plugged with
debris or solidified oil/
shortening in the Power
Shower tubing.
Move the filter handle to the OFF Position and
remove Power Shower. Remove the clean-out
plugs and place the unit in a pan of hot water for
several minutes to melt the oil/shortening. Insert a
straightened paper clip or similarly sized wire into
each hole to clear any blockages. Replace and
tighten clean-out screws. Verify that gasket and O-
ring are in place and in good condition.
Completely dry, then reinstall
the Power Shower, ensuring
that it seats properly in its
receptacle. Move the filter
handle to the ON position.
Is the Power
Shower spraying
properly?
Yes
No
POWER SHOWER
NOT SPRAYING
PROPERLY.
How much oil is
coming out of the
Power Shower?
Little or none, and
nothing is squirting
out around gasket.
Oil/shortening is not reaching the
Power Shower. Ensure that the Power
Shower receptacle in the frypot is not
obstructed. If it is clear, refer to the
Troubleshooting Guide on page 6-6.
Problem
resolved.
Problem is beyond
scope of operator
troubleshooting. Call FASC or
Frymaster Service
Department.
6-8
Plenty, but it is
also squirting out
around gasket.
Probable causes are
missing/worn O-rings and
gasket on Power Shower or
no filter paper in the filter
pan (causing too much
pressure).
Replace O-rings and
gasket or install filter
paper, whichever is
appropriate.
Is Power
Yes
Shower spraying
properly?
No