3. The computer will call for heat constantly. The heat light will remain on until fryer is within
11°F (6°C) of setpoint.
4. Once the fryer is at setpoint, check recovery time by pressing the
in the left display.
5. Enter 1, 6, 5, 2 in that sequence. The recovery time will appear in both displays for 5 seconds.
3.2.5 Temperature Selection—Fahrenheit to Celsius
1. To change the computer temperature from Fahrenheit to Celsius or Celsius to Fahrenheit, press
either
switch.
switch. CODE will appear in the left display.
2. Press the
3. Enter 1, 6, 5, 8 in that sequence. The computer will automatically convert the temperature from
Fahrenheit to Celsius or Celsius to Fahrenheit.
4. Press the
switch to display the temperature in the newly selected mode.
3.2.6 Constant Oil Temperature Display Mode
1. To program constant temperature display, press the
switch. CODE will appear in the left display.
2. Press the
3. Enter 1, 6, 5, L in that sequence. The cooking oil/shortening temperature will display constantly
in the right display on a full-pot and in both displays on a split-pot.
NOTE: During the product cooking process, the cooking time will not be displayed but timing will
be taking place.
4. To remove the constant oil-temperature display and display the cooking time, repeat Step 2 and
Step 3.