6.2.2 Fryer Heating Oil (cont.)
Continued from previous page
24 Volts supplied to Latching
Contactor and contactor closes?
As heat light illuminates, right HT
LED comes on (both HT LED's light
for DV)?
24 VAC supplied to heat
contactor and heating
contactor closes?
Elements heat
and draw proper
Continued on next page
YES
YES
YES
amps?
YES
1. Defective latching relay
2. Broken or improper wire connection
NO
3. Defective interface board
4. Defective latching contactor
1. Defective latching relay
2. Broken or improper wire connection
NO
3. Defective interface board
4. Defective latching contactor
1. Defective heating contactor
NO
2. Broken or defective wiring connection
3. Defective interface board
1. Defective heating contactor
2. Defective heating element
NO
3. Broken or defective wiring connection
4. Improper wire connection
6-4