6.2.2 Fryer Heating Oil
Turn the fryer ON and set the
temperature at least 45° F
above temperature of cooking
oil.
Heat light on (may cycle during melt)
COMPUTER
Alternating or constant LOW TEMP is displayed
CONTROLLER
Power Light ON
Right HI LED is ON for Full-Vats?
Both HI LED's ON for Dual-Vats
Continued on next page
YES
NO
YES
6-3
COMPUTER (CMIII)
1. "_ _ _ _ _" displayed, indicates oil temperature is
within 21° F (12° C) of setpoint
2. HI indicates oil temperature is 21° F (12° C) or
higher than the setpoint
3. HOT indicates the oil temperature is higher than
410° F (210° C) [395° F (202° C)] for European
Community H14/H17/H22 fryers
4. PROB indicates a problem in the temperature
measuring circuit including probe
5. HELP indicates a latching problem
6. Defective computer
7. Broken or improper wire connection
NO
8. Triac-Controlling Computer fryer - defective triacs
ANALOG CONTROLLER
1. Trouble light indicates:
a. Oil temperature is above the accepted range
b. Problem in temperature measuring circuit
including probe
2. Heat light and Trouble light on indicates a latching
problem
3. Defective controller
4. Broken or improper wire connection
DIGITAL CONTROLLER
1. HOT indicates the oil temperature is higher than
the accepted range
2. PROB indicates a problem in the temperature
measuring circuit including probe
3. HELP indicates a latching problem
4. Defective controller
5. Broken or improper wire connection
6. Triac Controlling Computer fryer - defective triacs
1. Open high limit
2. Open drain valve microswitch
3. Broken or defective wiring connection
4. Defective latching relay