3.2.3 Boil Feature
Do not drain water or boil-out solution into the filtration system. Irreparable damage will
1. Before switching the fryer(s) ON, close the frypot drain valve(s). Fill empty frypot with mixture
of cold water and detergent. Follow detergent instructions when mixing.
NOTE: Boil Mode will not turn on both sides of computer. Each side will have to be turned on
separately.
2. To program computer for Boil Feature, press either
3. Press the
switch. CODE will appear in the left display.
4. Enter 1, 6, 5, 3 in that sequence. The right display will read BOIL. The temperature is
automatically set for 195° F (91° C). The fryer will attain this temperature and remain there until
either
switch is pressed, which cancels the boil-out mode. In high-altitude locations,
constantly monitor the fryer for over-boil conditions. If over-boil occurs, turn off fryer
immediately, allow to cool, and re-enter boil-out mode to continue the boil-out operation.
3.2.4 Fryer Recovery Time Check
3.2.4.1 Fryers without Solid State Relays (No "T" in suffix)
Recovery Time - An acceptable recovery time is 100 seconds or less.
1. To check recovery time, press the
2. Enter 1, 6, 5, 2 in that sequence. The recovery time will appear in both displays for 5 seconds.
3.2.4.2 Fryers with Solid State Relays ("T" in suffix)
Due to the energy saving feature on solid-state relay-equipped fryers ("T" suffix in the model
number), the normal recovery check will provide invalid information and the fryer will appear not to
be working properly. To perform a valid recovery test the energy saving feature must be by-passed.
Recovery checks should be made monthly, or if the performance of the fryer is suspect.
1. Ensure the vat is properly filled with shortening to the appropriate oil-level line.
2. With the vat temperature above 200°F (95°C) and below 250°F (120°C) activate the R button for
full-vat. (L for left split-vat and R for right split-vat).
CAUTION
result and void the warranty.
switch. CODE will appear in the left display.